Ferroamp EnergyHub
Modbus TCP has to be enabled for the EnergyHub by the installer or Ferroamp support. The interface is only reachable via the EnergyHub's Ethernet interface. Grid values are measured by the external current transformers (CTs) at the grid connection point.
Podporované funkce
- Řízení baterie: Externí řízení nabíjení a vybíjení domácí baterie pomocí evcc.
Oblasti využití
- Měřič sítě
- Solární výroba
- Baterie
Parametry
| Název | Popis | Hodnota | Úroveň |
|---|---|---|---|
id | Modbus ID | int | povinné |
host | IP adresa nebo název hostitele | povinné | |
port | Port | int | povinné |
maxchargepower [W] | Maximum charge power For forced charging of the battery. | volitelné | |
maxdischargepower [W] | Maximum discharge power Maximum discharge power of the storage. | volitelné | |
minsoc [%] | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | volitelné | |
maxsoc [%] | Maximum charge Upper limit as configured on the battery system. Used by optimizer and for grid charging. | volitelné |
Příklad konfigurace pro evcc.yaml
Pokud nechcete konfigurovat přes uživatelské rozhraní, můžete místo toho použít tento blok YAML.
meters: - name: my_grid type: template template: ferroamp-energyhub usage: grid
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 502 # Portmeters: - name: my_pv type: template template: ferroamp-energyhub usage: pv
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 502 # Portmeters: - name: my_battery type: template template: ferroamp-energyhub usage: battery
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 502 # Port maxchargepower: # Maximum charge power (W), For forced charging of the battery. maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional) maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional)