ioBroker
The rest-api adapter (not simple-api) must be installed on the ioBroker instance being used. It must be configured as an extension of a web adapter.
Authentication can only be performed using basic authentication. If no password is provided, no authentication will be performed.
When specifying the entities for the individual measured values, ensure that they are correctly URL-encoded.
For example, shelly.0.SHEM-3#8CAAB561991E#1.Total.ConsumedPower becomes shelly.0.SHEM-3%238CAAB561991E%231.Total.ConsumedPower
Oblasti využití
- Měřič sítě
- Solární výroba
- Baterie
- Měřič nabíječky
Parametry
| Název | Popis | Hodnota | Úroveň |
|---|---|---|---|
uri | The full uri of the host to query HTTP(S) address | volitelné | |
user | Username e.g. email address, user id, etc. | volitelné | |
password | Password Service account password | volitelné | |
power [W] | Power | volitelné | |
soc [%] | State of Charge | volitelné | |
capacity [kWh] | Battery capacity | volitelné | |
minsoc [%] | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | volitelné | |
maxsoc [%] | Maximum charge Upper limit as configured on the battery system. Used by optimizer and for grid charging. | volitelné | |
cache | Cache Time interval for data refresh | pokročilé | |
energy [kWh] | Meter reading | pokročilé | |
currentL1 [A] | L1 current | pokročilé | |
currentL2 [A] | L2 current | pokročilé | |
currentL3 [A] | L3 current | pokročilé | |
maxchargepower [W] | Maximum charge power For forced charging of the battery. | pokročilé | |
maxdischargepower [W] | Maximum discharge power Maximum discharge power of the storage. | pokročilé | |
maxacpower [W] | Maximum AC power of the hybrid inverter | pokročilé |
Příklad konfigurace pro evcc.yaml
Pokud nechcete konfigurovat přes uživatelské rozhraní, můžete místo toho použít tento blok YAML.
meters: - name: my_grid type: template template: iobroker usage: grid uri: https://iobroker.homelab.lan:8082 # The full uri of the host to query, HTTP(S) address user: # Username, e.g. email address, user id, etc. (optional) password: # Password, Service account password (optional) power: # Power (W), optional soc: # State of Charge (%), optional cache: 5m # Cache, Time interval for data refresh (optional) energy: # Meter reading (kWh), optional currentL1: # L1 current (A), optional currentL2: # L2 current (A), optional currentL3: # L3 current (A), optionalmeters: - name: my_pv type: template template: iobroker usage: pv uri: https://iobroker.homelab.lan:8082 # The full uri of the host to query, HTTP(S) address user: # Username, e.g. email address, user id, etc. (optional) password: # Password, Service account password (optional) power: # Power (W), optional soc: # State of Charge (%), optional cache: 5m # Cache, Time interval for data refresh (optional) energy: # Meter reading (kWh), optional currentL1: # L1 current (A), optional currentL2: # L2 current (A), optional currentL3: # L3 current (A), optional maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optionalmeters: - name: my_battery type: template template: iobroker usage: battery uri: https://iobroker.homelab.lan:8082 # The full uri of the host to query, HTTP(S) address user: # Username, e.g. email address, user id, etc. (optional) password: # Password, Service account password (optional) power: # Power (W), optional soc: # State of Charge (%), optional capacity: 50 # Battery capacity (kWh), optional minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional) maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional) cache: 5m # Cache, Time interval for data refresh (optional) energy: # Meter reading (kWh), optional currentL1: # L1 current (A), optional currentL2: # L2 current (A), optional currentL3: # L3 current (A), optional maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional) maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)meters: - name: my_charger type: template template: iobroker usage: charge uri: https://iobroker.homelab.lan:8082 # The full uri of the host to query, HTTP(S) address user: # Username, e.g. email address, user id, etc. (optional) password: # Password, Service account password (optional) power: # Power (W), optional soc: # State of Charge (%), optional cache: 5m # Cache, Time interval for data refresh (optional) energy: # Meter reading (kWh), optional currentL1: # L1 current (A), optional currentL2: # L2 current (A), optional currentL3: # L3 current (A), optional