RCT Power
Podporované funkce
- Řízení baterie: Externí řízení nabíjení a vybíjení domácí baterie pomocí evcc.
- Omezitelné: Výkon střídače lze omezit (např. § 9 EEG). Viz Externí limit.
Oblasti využití
- Měřič sítě
- Solární výroba
- Baterie
Parametry
| Název | Popis | Hodnota | Úroveň |
|---|---|---|---|
host | IP address or hostname | volitelné | |
port | Port | volitelné | |
capacity [kWh] | Battery capacity | volitelné | |
minsoc [%] | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | volitelné | |
maxsoc [%] | Maximum charge Upper limit as configured on the battery system. Used by optimizer and for grid charging. | volitelné | |
capacity2 [kWh] | Battery capacity of the second battery | volitelné | |
maxacpower [W] | Maximum AC power of the hybrid inverter | pokročilé | |
externalpower | External power Query external power of all devices connected to S0 | pokročilé | |
maxchargepower [W] | Maximum charge power For forced charging of the battery. | pokročilé | |
maxdischargepower [W] | Maximum discharge power Maximum discharge power of the storage. | pokročilé | |
cache | Cache Time interval for data refresh | pokročilé |
Příklad konfigurace pro evcc.yaml
Pokud nechcete konfigurovat přes uživatelské rozhraní, můžete místo toho použít tento blok YAML.
meters: - name: my_grid type: template template: rct-power usage: grid host: 192.0.2.2 # IP address or hostname port: 8899 # Port cache: 30s # Cache, Time interval for data refresh (optional)meters: - name: my_pv type: template template: rct-power usage: pv host: 192.0.2.2 # IP address or hostname port: 8899 # Port maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optional externalpower: # External power, Query external power of all devices connected to S0 (optional) cache: 30s # Cache, Time interval for data refresh (optional)meters: - name: my_battery type: template template: rct-power usage: battery host: 192.0.2.2 # IP address or hostname port: 8899 # Port capacity: 50 # Battery capacity (kWh), optional minsoc: 7 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional) maxsoc: 97 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional) capacity2: 50 # Battery capacity of the second battery (kWh), optional maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional) maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional) cache: 30s # Cache, Time interval for data refresh (optional)