Přeskočit na obsah
chytré nabíjení

SunEnergyXT SunEnergyXT 500 / 500 PRO

The battery's local mode must be enabled in the manufacturer's app. Furthermore, the device's IP address must be set to a fixed, permanent IP address in the router. An external meter (e.g., Shelly) measuring the grid connection point must be connected to the battery via the manufacturer's app. It is required for the grid usage, and also for the battery usage, because the normal battery mode enables the device's zero feed-in regulation, which reads this meter.

Podporované funkce

  • Řízení baterie: Externí řízení nabíjení a vybíjení domácí baterie pomocí evcc.

Oblasti využití

  • Měřič sítě
  • Solární výroba
  • Baterie

Parametry

NázevPopisHodnotaÚroveň
modelModel

standard for the SunEnergyXT 500, pro for the SunEnergyXT 500 PRO. Determines the maximum AC and discharge power (800 W resp. 2400 W).

volitelné
hostIP address or hostname
Příklad: 192.0.2.2
volitelné
capacity [kWh]Battery capacity

Total storage capacity: head unit 5 kWh, each extension pack adds 5 kWh. So 5 (head unit only), 10 (+1 extension) or 15 (+2 extensions). The number of detected battery packs is reported in the ON field of /read.

Výchozí: 5
Příklad: 50
volitelné
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Výchozí: 0
Příklad: 25
volitelné
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and for grid charging.

Výchozí: 100
Příklad: 95
volitelné
maxacpower [W]Maximum AC power of the hybrid inverter
Výchozí: 0
Příklad: 5000
pokročilé
maxchargepower [W]Maximum charge power

For forced charging of the battery.

Výchozí: 2400
pokročilé
maxdischargepower [W]Maximum discharge power

Maximum discharge power of the storage.

pokročilé
cacheCache

Time interval for data refresh

Výchozí: 2s
Příklad: 5m
pokročilé
timeoutTimeout
Výchozí: 10s
Příklad: 10s
pokročilé
Příklad konfigurace pro evcc.yaml

Pokud nechcete konfigurovat přes uživatelské rozhraní, můžete místo toho použít tento blok YAML.

meters:
- name: my_grid
type: template
template: sunenergyxt-500
usage: grid
model: # Model, `standard` for the SunEnergyXT 500, `pro` for the SunEnergyXT 500 PRO. Determines the maximum AC and discharge power (800 W resp. 2400 W). [standard, pro]
host: 192.0.2.2 # IP address or hostname
cache: 2s # Cache, Time interval for data refresh (optional)
timeout: 10s # Timeout, optional
meters:
- name: my_pv
type: template
template: sunenergyxt-500
usage: pv
model: # Model, `standard` for the SunEnergyXT 500, `pro` for the SunEnergyXT 500 PRO. Determines the maximum AC and discharge power (800 W resp. 2400 W). [standard, pro]
host: 192.0.2.2 # IP address or hostname
maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optional
cache: 2s # Cache, Time interval for data refresh (optional)
timeout: 10s # Timeout, optional
meters:
- name: my_battery
type: template
template: sunenergyxt-500
usage: battery
model: # Model, `standard` for the SunEnergyXT 500, `pro` for the SunEnergyXT 500 PRO. Determines the maximum AC and discharge power (800 W resp. 2400 W). [standard, pro]
host: 192.0.2.2 # IP address or hostname
capacity: 5 # Battery capacity (kWh), Total storage capacity: head unit 5 kWh, each extension pack adds 5 kWh. So 5 (head unit only), 10 (+1 extension) or 15 (+2 extensions). The number of detected battery packs is reported in the `ON` field of `/read`. (optional)
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional)
maxchargepower: 2400 # Maximum charge power (W), For forced charging of the battery. (optional)
maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)
cache: 2s # Cache, Time interval for data refresh (optional)
timeout: 10s # Timeout, optional