VARTA element backup

PV is only available with an additional PV sensor, as the power of the devices registered in the SUNSPEC Manager is not output via Modbus. Element backup requires at least firmware version F21000612. The firmware update is not rolled out automatically, but can be released upon request by VARTA's technical service.

Oblasti využití

  • Měřič sítě
  • Solární výroba
  • Baterie

Parametry

NázevPopisHodnotaÚroveň
idModbus ID
Výchozí: 1
intpovinné
hostIP adresa nebo název hostitele
Příklad: 192.0.2.2
povinné
portPort
Výchozí: 502
intpovinné
capacity [kWh]Battery capacity
Příklad: 50
volitelné
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Výchozí: 0
Příklad: 25
volitelné
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and for grid charging.

Výchozí: 100
Příklad: 95
volitelné
maxchargepower [W]Maximum charge power

For forced charging of the battery.

pokročilé
maxdischargepower [W]Maximum discharge power

Maximum discharge power of the storage.

Výchozí: 4000
pokročilé
watchdogWatchdog
Výchozí: 120s
pokročilé
Příklad konfigurace pro evcc.yaml

Pokud nechcete konfigurovat přes uživatelské rozhraní, můžete místo toho použít tento blok YAML.

meters:
- name: my_grid
type: template
template: varta
usage: grid
# Modbus TCP
modbus: tcpip
id: 255
host: # Hostname
port: 502 # Port
meters:
- name: my_pv
type: template
template: varta
usage: pv
# Modbus TCP
modbus: tcpip
id: 255
host: # Hostname
port: 502 # Port
meters:
- name: my_battery
type: template
template: varta
usage: battery
# Modbus TCP
modbus: tcpip
id: 255
host: # Hostname
port: 502 # Port
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional)
maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional)
maxdischargepower: 4000 # Maximum discharge power (W), Maximum discharge power of the storage. (optional)
watchdog: 120s # Watchdog, optional