Connect the relay contacts of the control box to the digital inputs of the module. The module must provide the inputs as discrete inputs (function code 02), a closed contact reads as active.

Parametry

NázevPopisHodnotaÚroveň
idModbus ID
Výchozí: 1
intpovinné
hostIP adresa nebo název hostitele
Příklad: 192.0.2.2
povinné
portPort
Výchozí: 502
intpovinné
maxconsumptionpower [W]Guaranteed minimum power (Pmin)

Power limit applied to the root circuit while the limit is active.

volitelné
w4inputW4 input

Digital input number for the W4 signal (Dimmer for controllable loads), counting from 1 (first input = 1)

Výchozí: 1
volitelné
w3inputW3 input

Digital input number for the W3 signal (Zero export, 0%), counting from 1 (first input = 1)

Výchozí: 2
volitelné
productionnominalmax [Wp]Installed generator power

Rated generator/module power of the installation (reference value according to § 9 EEG).

volitelné
s1inputS1 input

Digital input number for the S1 signal (60% export power limit), counting from 1 (first input = 1)

Příklad: 3
volitelné
s2inputS2 input

Digital input number for the S2 signal (30% export power limit), counting from 1 (first input = 1)

Příklad: 4
volitelné
Příklad konfigurace pro evcc.yaml

Pokud nechcete konfigurovat přes uživatelské rozhraní, můžete místo toho použít tento blok YAML.

hems:
type: template
template: fnn-modbus
# Modbus TCP
modbus: tcpip
id: 1
host: # Hostname
port: 502 # Port
maxconsumptionpower: # Guaranteed minimum power (Pmin) (W), Power limit applied to the root circuit while the limit is active.
w4input: 1 # W4 input, Digital input number for the W4 signal (Dimmer for controllable loads), counting from 1 (first input = 1)
w3input: 2 # W3 input, Digital input number for the W3 signal (Zero export, 0%), counting from 1 (first input = 1)
productionnominalmax: # Installed generator power (Wp), Rated generator/module power of the installation (reference value according to § 9 EEG). (optional)
s1input: 3 # S1 input, Digital input number for the S1 signal (60% export power limit), counting from 1 (first input = 1) (optional)
s2input: 4 # S2 input, Digital input number for the S2 signal (30% export power limit), counting from 1 (first input = 1) (optional)