my-PV AC•THOR 9s

Tato stránka zobrazuje verzi nightly. Přepněte na verzi release.

Use the local web interface of AC•THOR to set the value "Power timeout" to a value slightly higher (e.g. + 5s) than the interval time of evcc. Use control type "Modbus TCP" and set loadpoint minimal current to 0.125A. If the heating element at the controlled output has < 9 kW, the scaling factor has to be calculated as follows: scale = 9000 / nominal power of the connected heater.

Operation mode M3: 9 + 9 kW with an additional heater connected to the relay output is supported. Without load measurement using my-PV meter, the "Load at relay" setting in the local web interface of the AC•THOR must be set to match the nominal power of the heating element at the relay. If the heater at the controlled output has < 9 kW, AC•THOR firmware a0022401 or higher is required and the value for "Load at relay" must be converted using the scaling factor as follows: Load at relay = nominal power of the heater at the relay * scale factor

Podporované funkce

  • Vestavěný měřič: Podpora vestavěného měřiče.

Parametry

NázevPopisHodnotaÚroveň
idModbus ID
Výchozí: 1
intpovinné
hostIP adresa nebo název hostitele
Příklad: 192.0.2.2
povinné
portPort
Výchozí: 502
intpovinné
tempsourceTemperature source
Výchozí: 1
volitelné
scaleScale factor for power target value
Výchozí: 1
volitelné
Příklad konfigurace pro evcc.yaml

Pokud nechcete konfigurovat přes uživatelské rozhraní, můžete místo toho použít tento blok YAML.

chargers:
- name: my_heating
type: template
template: ac-thor
# Modbus TCP
modbus: tcpip
id: 1
host: # Hostname
port: 502 # Port
tempsource: 1 # Temperature source, [1, 2, 3] (optional)
scale: 1 # Scale factor for power target value, optional