Přeskočit na obsah
chytré nabíjení

Vaillant SensoNET (API)

Tato stránka zobrazuje verzi nightly. Přepněte na verzi release.

The boost function heats hot water or a boost zone. The boost zone is identified by the ID. The boost temperature is specified in degrees Celsius. If boost temperature is specified, the boost zone is activated, otherwise hot water. Note, if the appliance's DHW operation mode is set to "off" so that evcc fully controls hot water, the appliance no longer runs its weekly legionella protection. Make sure to periodically heat the water to disinfection temperature yourself (e.g. via time program or a forced boost).

Parametry

NázevPopisHodnotaÚroveň
userUsername

e.g. email address, user id, etc.

volitelné
passwordPassword

Service account password

volitelné
realmRegion
Výchozí: germany
volitelné
zoneBoost zone IDvolitelné
setpointBoost temperaturevolitelné
systemName of the system

Required if multiple systems are present in the account

volitelné
reboostReboost interval

Wait time after which Boost is started again.

Výchozí: 15m
pokročilé
hysteresis [°C]Reboost Hysteresispokročilé
Příklad konfigurace pro evcc.yaml

Pokud nechcete konfigurovat přes uživatelské rozhraní, můžete místo toho použít tento blok YAML.

chargers:
- name: my_heating
type: template
template: vaillant
user: # Username, e.g. email address, user id, etc. (optional)
password: # Password, Service account password (optional)
realm: germany # Region, [albania, austria, belgium, bosnia, bulgaria, croatia, cyprus, czechrepublic, denmark, estonia, finland, france, georgia, germany, greece, hungary, ireland, italy, kosovo, latvia, lithuania, luxembourg, moldavia, netherlands, new-zealand, north-macedonia, norway, poland, portugal, romania, serbia, slovakia, slovenia, spain, sweden, switzerland, turkiye, ukraine, unitedkingdom, uzbekistan] (optional)
zone: # Boost zone ID, optional
setpoint: # Boost temperature, optional
system: # Name of the system, Required if multiple systems are present in the account (optional)
reboost: 15m # Reboost interval, Wait time after which Boost is started again. (optional)
hysteresis: # Reboost Hysteresis (°C), optional