Anker SOLIX X1 Hybrid Inverter

Tato stránka zobrazuje verzi nightly. Přepněte na verzi release.

The Modbus TCP interface must be enabled in the Anker app. This configuration was tested with the Firmware Version 1.0.16.1. Older or newer Firmware Versions may use different register addresses and therefore deliver incorrect data. evcc can charge the battery from the grid (work mode third-party control with the maximum charge power maxchargepower) and return it to self-consumption. A work mode set in the Anker app is overwritten. evcc only writes to the X1 when a battery function is enabled (grid charging, discharge lock, automatic optimizer control or an external battery mode). Otherwise the X1 keeps the mode set in the Anker app. The X1 does not return to self-consumption on its own: if evcc stops unexpectedly while grid charging, the X1 keeps charging until evcc sets a mode again. Holding is not supported and falls back to normal operation: the X1 offers no way to block discharging while still storing PV surplus.

Podporované funkce

  • Řízení baterie: Externí řízení nabíjení a vybíjení domácí baterie pomocí evcc.

Oblasti využití

  • Měřič sítě
  • Solární výroba
  • Baterie

Parametry

NázevPopisHodnotaÚroveň
idModbus ID
Výchozí: 1
intpovinné
hostIP adresa nebo název hostitele
Příklad: 192.0.2.2
povinné
portPort
Výchozí: 502
intpovinné
maxchargepower [W]Maximum charge power

Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power.

volitelné
capacity [kWh]Battery capacity
Příklad: 50
volitelné
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Výchozí: 0
Příklad: 25
volitelné
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging.

Výchozí: 100
Příklad: 95
volitelné
maxacpower [W]Maximum AC power of the hybrid inverter
Výchozí: 0
Příklad: 5000
pokročilé
maxdischargepower [W]Maximum discharge power

Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging.

pokročilé
watchdogWatchdog
Výchozí: 60s
pokročilé
Příklad konfigurace pro evcc.yaml

Pokud nechcete konfigurovat přes uživatelské rozhraní, můžete místo toho použít tento blok YAML.

meters:
- name: my_grid
type: template
template: anker-solix-x1
usage: grid
# Modbus TCP
modbus: tcpip
id: 1
host: # Hostname
port: 502 # Port
watchdog: 60s # Watchdog, optional
meters:
- name: my_pv
type: template
template: anker-solix-x1
usage: pv
# Modbus TCP
modbus: tcpip
id: 1
host: # Hostname
port: 502 # Port
maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optional
watchdog: 60s # Watchdog, optional
meters:
- name: my_battery
type: template
template: anker-solix-x1
usage: battery
# Modbus TCP
modbus: tcpip
id: 1
host: # Hostname
port: 502 # Port
maxchargepower: # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power.
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional)
maxdischargepower: # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. (optional)
watchdog: 60s # Watchdog, optional