Parametry
| Název | Popis | Hodnota | Úroveň |
|---|---|---|---|
host | IP address or hostname | volitelné | |
token | Token Required if Envoy Firmware D7.x.xxx. Token is valid for one year. Instructions for obtaining a token via web UI: enphase.com | volitelné | |
capacity [kWh] | Battery capacity | volitelné | |
minsoc [%] | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | volitelné | |
maxsoc [%] | Maximum charge Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. | volitelné | |
schema | Schema | pokročilé | |
battery_type | Enphase Battery Type (AC or IQ) Select 'iq' for new Enphase IQ Batteries. Leave at default 'ac' for older generation AC Batteries. | pokročilé | |
maxchargepower [W] | Maximum charge power Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. | pokročilé | |
maxdischargepower [W] | Maximum discharge power Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. | pokročilé | |
cache | Cache Time interval for data refresh | pokročilé | |
timeout | Timeout | pokročilé |
Příklad konfigurace pro evcc.yaml
Pokud nechcete konfigurovat přes uživatelské rozhraní, můžete místo toho použít tento blok YAML.
meters: - name: my_grid type: template template: enphase usage: grid host: 192.0.2.2 # IP address or hostname token: # Token, Required if Envoy Firmware D7.x.xxx. Token is valid for one year. Instructions for obtaining a token via web UI: [enphase.com](https://enphase.com/download/accessing-iq-gateway-local-apis-or-local-ui-token-based-authentication) (optional) schema: https # Schema, [https, http] (optional) cache: 1s # Cache, Time interval for data refresh (optional) timeout: 10s # Timeout, optionalmeters: - name: my_pv type: template template: enphase usage: pv host: 192.0.2.2 # IP address or hostname token: # Token, Required if Envoy Firmware D7.x.xxx. Token is valid for one year. Instructions for obtaining a token via web UI: [enphase.com](https://enphase.com/download/accessing-iq-gateway-local-apis-or-local-ui-token-based-authentication) (optional) schema: https # Schema, [https, http] (optional) cache: 1s # Cache, Time interval for data refresh (optional) timeout: 10s # Timeout, optionalmeters: - name: my_battery type: template template: enphase usage: battery host: 192.0.2.2 # IP address or hostname token: # Token, Required if Envoy Firmware D7.x.xxx. Token is valid for one year. Instructions for obtaining a token via web UI: [enphase.com](https://enphase.com/download/accessing-iq-gateway-local-apis-or-local-ui-token-based-authentication) (optional) capacity: 50 # Battery capacity (kWh), optional minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional) maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional) schema: https # Schema, [https, http] (optional) battery_type: ac # Enphase Battery Type (AC or IQ), Select 'iq' for new Enphase IQ Batteries. Leave at default 'ac' for older generation AC Batteries. [ac, iq] (optional) maxchargepower: # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. (optional) maxdischargepower: # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. (optional) cache: 1s # Cache, Time interval for data refresh (optional) timeout: 10s # Timeout, optional