Přeskočit na obsah
chytré nabíjení

Enphase IQ Gateway

Tato stránka zobrazuje verzi nightly. Přepněte na verzi release.

Oblasti využití

  • Měřič sítě
  • Solární výroba
  • Baterie

Parametry

NázevPopisHodnotaÚroveň
hostIP address or hostname
Příklad: 192.0.2.2
volitelné
tokenToken

Required if Envoy Firmware D7.x.xxx. Token is valid for one year. Instructions for obtaining a token via web UI: enphase.com

volitelné
capacity [kWh]Battery capacity
Příklad: 50
volitelné
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Výchozí: 0
Příklad: 25
volitelné
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging.

Výchozí: 100
Příklad: 95
volitelné
schemaSchema
Výchozí: https
pokročilé
battery_typeEnphase Battery Type (AC or IQ)

Select 'iq' for new Enphase IQ Batteries. Leave at default 'ac' for older generation AC Batteries.

Výchozí: ac
pokročilé
maxchargepower [W]Maximum charge power

Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power.

pokročilé
maxdischargepower [W]Maximum discharge power

Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging.

pokročilé
cacheCache

Time interval for data refresh

Výchozí: 1s
Příklad: 5m
pokročilé
timeoutTimeout
Výchozí: 10s
Příklad: 10s
pokročilé
Příklad konfigurace pro evcc.yaml

Pokud nechcete konfigurovat přes uživatelské rozhraní, můžete místo toho použít tento blok YAML.

meters:
- name: my_grid
type: template
template: enphase
usage: grid
host: 192.0.2.2 # IP address or hostname
token: # Token, Required if Envoy Firmware D7.x.xxx. Token is valid for one year. Instructions for obtaining a token via web UI: [enphase.com](https://enphase.com/download/accessing-iq-gateway-local-apis-or-local-ui-token-based-authentication) (optional)
schema: https # Schema, [https, http] (optional)
cache: 1s # Cache, Time interval for data refresh (optional)
timeout: 10s # Timeout, optional
meters:
- name: my_pv
type: template
template: enphase
usage: pv
host: 192.0.2.2 # IP address or hostname
token: # Token, Required if Envoy Firmware D7.x.xxx. Token is valid for one year. Instructions for obtaining a token via web UI: [enphase.com](https://enphase.com/download/accessing-iq-gateway-local-apis-or-local-ui-token-based-authentication) (optional)
schema: https # Schema, [https, http] (optional)
cache: 1s # Cache, Time interval for data refresh (optional)
timeout: 10s # Timeout, optional
meters:
- name: my_battery
type: template
template: enphase
usage: battery
host: 192.0.2.2 # IP address or hostname
token: # Token, Required if Envoy Firmware D7.x.xxx. Token is valid for one year. Instructions for obtaining a token via web UI: [enphase.com](https://enphase.com/download/accessing-iq-gateway-local-apis-or-local-ui-token-based-authentication) (optional)
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional)
schema: https # Schema, [https, http] (optional)
battery_type: ac # Enphase Battery Type (AC or IQ), Select 'iq' for new Enphase IQ Batteries. Leave at default 'ac' for older generation AC Batteries. [ac, iq] (optional)
maxchargepower: # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. (optional)
maxdischargepower: # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. (optional)
cache: 1s # Cache, Time interval for data refresh (optional)
timeout: 10s # Timeout, optional