Tesla Powerwall (pypowerwall-server)
Uses pypowerwall-server as backend. Reads come from its proxy API, battery control uses its authenticated /control/* routes. For battery control, PW_CONTROL_SECRET must be set on the server; reserve_hold requires pypowerwall-server v0.10.0 or later.
Since pypowerwall-server v0.14.0 the server can optionally serve HTTPS on port 8775. Without a TLS reverse proxy or the HTTPS listener it stays plain HTTP; with controlSecret, prefer HTTPS or a trusted network.
Podporované funkce
- Řízení baterie: Externí řízení nabíjení a vybíjení domácí baterie pomocí evcc.
Oblasti využití
- Měřič sítě
- Solární výroba
- Baterie
Parametry
| Název | Popis | Hodnota | Úroveň |
|---|---|---|---|
host | IP address or hostname | volitelné | |
port | Port | volitelné | |
capacity [kWh] | Battery capacity | volitelné | |
minsoc [%] | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | volitelné | |
maxsoc [%] | Maximum charge Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. | volitelné | |
schema | Schema Use https when the server has PW_HTTPS enabled or is behind a TLS reverse proxy. Set the port to the HTTPS port, usually 8775, when using the server's HTTPS listener. | pokročilé | |
insecure | Accept self-signed certificates | pokročilé | |
cache | Cache Time interval for data refresh | pokročilé | |
controlSecret | Control secret Value of PW_CONTROL_SECRET. Required for battery control, omit for read-only use. | pokročilé | |
maxchargepower [W] | Maximum charge power Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. | pokročilé | |
maxdischargepower [W] | Maximum discharge power Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. | pokročilé |
Příklad konfigurace pro evcc.yaml
Pokud nechcete konfigurovat přes uživatelské rozhraní, můžete místo toho použít tento blok YAML.
meters: - name: my_grid type: template template: tesla-powerwall-pypowerwall-server usage: grid host: 192.0.2.2 # IP address or hostname port: 8675 # Port, optional schema: http # Schema, Use https when the server has PW_HTTPS enabled or is behind a TLS reverse proxy. Set the port to the HTTPS port, usually 8775, when using the server's HTTPS listener. [https, http] (optional) insecure: # Accept self-signed certificates, optional cache: 1s # Cache, Time interval for data refresh (optional)meters: - name: my_pv type: template template: tesla-powerwall-pypowerwall-server usage: pv host: 192.0.2.2 # IP address or hostname port: 8675 # Port, optional schema: http # Schema, Use https when the server has PW_HTTPS enabled or is behind a TLS reverse proxy. Set the port to the HTTPS port, usually 8775, when using the server's HTTPS listener. [https, http] (optional) insecure: # Accept self-signed certificates, optional cache: 1s # Cache, Time interval for data refresh (optional)meters: - name: my_battery type: template template: tesla-powerwall-pypowerwall-server usage: battery host: 192.0.2.2 # IP address or hostname port: 8675 # Port, optional capacity: 50 # Battery capacity (kWh), optional minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional) maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional) schema: http # Schema, Use https when the server has PW_HTTPS enabled or is behind a TLS reverse proxy. Set the port to the HTTPS port, usually 8775, when using the server's HTTPS listener. [https, http] (optional) insecure: # Accept self-signed certificates, optional cache: 1s # Cache, Time interval for data refresh (optional) controlSecret: # Control secret, Value of PW_CONTROL_SECRET. Required for battery control, omit for read-only use. (optional) maxchargepower: # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. (optional) maxdischargepower: # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. (optional)