Sonnen sonnenBatterie
For active battery control, the "JSON Write API" must be activated via the sonnenBatterie web interface (under Software-Integration) and the API token generated there must be entered in the battery configuration under token.
The two operating modes supported for the sonnenBatterie are "self-consumption" (default) and "time-of-use". The mode can be adapted to the configuration of the sonnenBatterie via the 'defaultmode' parameter.
The power for grid charging can be adapted to the inverter power of the sonnenBatterie via the maxchargepower parameter.
Podporované funkce
- Řízení baterie: Externí řízení nabíjení a vybíjení domácí baterie pomocí evcc.
Oblasti využití
- Měřič sítě
- Solární výroba
- Baterie
Parametry
| Název | Popis | Hodnota | Úroveň |
|---|---|---|---|
host | IP address or hostname | volitelné | |
defaultmode | Default mode for battery control Inverter falls back to this mode after charging the battery or after stopping discharge. | volitelné | |
port | Port | volitelné | |
capacity [kWh] | Battery capacity | volitelné | |
minsoc [%] | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | volitelné | |
maxsoc [%] | Maximum charge Upper limit as configured on the battery system. Used by optimizer and for grid charging. | volitelné | |
token | Token API Token (required for active battery control) | volitelné | |
maxchargepower [W] | Maximum charge power For forced charging of the battery. | pokročilé | |
maxdischargepower [W] | Maximum discharge power Maximum discharge power of the storage. | pokročilé | |
cache | Cache Time interval for data refresh | pokročilé |
Příklad konfigurace pro evcc.yaml
Pokud nechcete konfigurovat přes uživatelské rozhraní, můžete místo toho použít tento blok YAML.
meters: - name: my_grid type: template template: sonnenbatterie usage: grid host: 192.0.2.2 # IP address or hostname port: 8080 # Port, optional cache: 1s # Cache, Time interval for data refresh (optional)meters: - name: my_pv type: template template: sonnenbatterie usage: pv host: 192.0.2.2 # IP address or hostname port: 8080 # Port, optional cache: 1s # Cache, Time interval for data refresh (optional)meters: - name: my_battery type: template template: sonnenbatterie usage: battery host: 192.0.2.2 # IP address or hostname defaultmode: self-consumption # Default mode for battery control, Inverter falls back to this mode after charging the battery or after stopping discharge. [self-consumption, time-of-use] port: 8080 # Port, optional capacity: 50 # Battery capacity (kWh), optional minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional) maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional) token: # Token, API Token (required for active battery control) (optional) maxchargepower: 3300 # Maximum charge power (W), For forced charging of the battery. (optional) maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional) cache: 1s # Cache, Time interval for data refresh (optional)