Přeskočit na obsah
chytré nabíjení

LG Heat pump water heater (ThinQ)

Tato stránka zobrazuje verzi nightly. Přepněte na verzi release.

Controls LG heat pump water heaters (e.g. WH27S) via the LG ThinQ Connect cloud API. A personal access token (PAT) must be created at https://connect-pat.lgthinq.com with the permissions "view devices", "view device status" and "control devices". evcc sets the water heater target temperature: the normal temperature outside of boost, the boost temperature during boost.

Parametry

NázevPopisHodnotaÚroveň
tokenPersonal access token (PAT)volitelné
countryCountry code

Country code of the LG account (ISO 3166-1 alpha-2)

Výchozí: DE
volitelné
deviceDevice ID

Required if multiple water heaters are present in the account

volitelné
normal [°C]Normal temperature

Target temperature outside of boost

Výchozí: 50
volitelné
setpoint [°C]Boost temperature

Target temperature during boost, must exceed the normal temperature

Výchozí: 60
volitelné
cacheCache

Time interval for data refresh

Výchozí: 1m
Příklad: 5m
pokročilé
Příklad konfigurace pro evcc.yaml

Pokud nechcete konfigurovat přes uživatelské rozhraní, můžete místo toho použít tento blok YAML.

chargers:
- name: my_heating
type: template
template: lg-thinq
token: # Personal access token (PAT)
country: DE # Country code, Country code of the LG account (ISO 3166-1 alpha-2) (optional)
device: # Device ID, Required if multiple water heaters are present in the account (optional)
normal: 50 # Normal temperature (°C), Target temperature outside of boost (optional)
setpoint: 60 # Boost temperature (°C), Target temperature during boost, must exceed the normal temperature (optional)
cache: 1m # Cache, Time interval for data refresh (optional)