Přeskočit na obsah
chytré nabíjení

IoTaWatt Energy Monitor

Tato stránka zobrazuje verzi nightly. Přepněte na verzi release.

Requires an IoTaWatt device accessible on the local network. Find available series names on the IoTaWatt status page (http://<device-host>). For single-phase setups, configure only the main series (e.g. GridNet, Solar). For three-phase, configure one series per phase (e.g. Grid_A, Grid_B, Grid_C).

Oblasti využití

  • Měřič sítě
  • Solární výroba
  • Měřič nabíječky

Parametry

NázevPopisHodnotaÚroveň
hostIP address or hostname
Příklad: 192.0.2.2
volitelné
seriesL1 / single-phase series

IoTaWatt series name (Watts). Check the IoTaWatt status page for available series.

Příklad: GridNet
volitelné
seriesL2L2 series (three-phase)

Series name for phase L2. Leave empty for single-phase.

pokročilé
seriesL3L3 series (three-phase)

Series name for phase L3. Leave empty for single-phase.

pokročilé
cacheCache

Time interval for data refresh

Výchozí: 2s
Příklad: 5m
pokročilé
Příklad konfigurace pro evcc.yaml

Pokud nechcete konfigurovat přes uživatelské rozhraní, můžete místo toho použít tento blok YAML.

meters:
- name: my_grid
type: template
template: iotawatt
usage: grid
host: 192.0.2.2 # IP address or hostname
series: GridNet # L1 / single-phase series, IoTaWatt series name (Watts). Check the IoTaWatt status page for available series.
seriesL2: # L2 series (three-phase), Series name for phase L2. Leave empty for single-phase. (optional)
seriesL3: # L3 series (three-phase), Series name for phase L3. Leave empty for single-phase. (optional)
cache: 2s # Cache, Time interval for data refresh (optional)
meters:
- name: my_pv
type: template
template: iotawatt
usage: pv
host: 192.0.2.2 # IP address or hostname
series: GridNet # L1 / single-phase series, IoTaWatt series name (Watts). Check the IoTaWatt status page for available series.
seriesL2: # L2 series (three-phase), Series name for phase L2. Leave empty for single-phase. (optional)
seriesL3: # L3 series (three-phase), Series name for phase L3. Leave empty for single-phase. (optional)
cache: 2s # Cache, Time interval for data refresh (optional)
meters:
- name: my_charger
type: template
template: iotawatt
usage: charge
host: 192.0.2.2 # IP address or hostname
series: GridNet # L1 / single-phase series, IoTaWatt series name (Watts). Check the IoTaWatt status page for available series.
seriesL2: # L2 series (three-phase), Series name for phase L2. Leave empty for single-phase. (optional)
seriesL3: # L3 series (three-phase), Series name for phase L3. Leave empty for single-phase. (optional)
cache: 2s # Cache, Time interval for data refresh (optional)