Bender CC613
The 'Modbus TCP Server' must be enabled. The setting 'Register Address Set' must NOT be set to 'Phoenix' or 'TQ-DM100'. Use the third selection labeled 'Ebee', 'Bender', 'MENNEKES' etc. Set 'Allow UID Disclose' to On.
Firmware 5.33 or higher is required for phase switching (if supported by the model). The 'SEMP interface' must be enabled, the 'SEMP Charging Mode' must be set to 'Surplus Charging'. Set 'Software function to use phase switching' to SEMP.
For charging stations with two charging points (e.g. AMEDIO, Twincharge), each charging point must be configured separately. Set charging point 1 to Port 502 and charging point 2 to Port 503.
Ondersteunde functies
- RFID: Geïntegreerde RFID-kaartlezer voor voertuigherkenning.
- Dimbaar: Het opgenomen vermogen kan worden verlaagd (bijv. § 14a EnWG). Zie Externe limiet.
Parameters
| Naam | Omschrijving | Waarde | Niveau |
|---|---|---|---|
id | Modbus-ID | int | verplicht |
host | IP-adres of hostnaam | verplicht | |
port | Poort | int | verplicht |
Configuratievoorbeeld voor evcc.yaml
Als u niet via de gebruikersinterface wilt configureren, kunt u ook dit YAML-blok gebruiken.
chargers: - name: my_charger type: template template: bender-cc
# Modbus TCP modbus: tcpip id: 255 host: # Hostname port: 502 # Port