OpenEVSE
Requires OpenEVSE WiFi firmware 4.1.9 or later. evcc controls the charger through its claims API;
the manual override on the charger (the On/Off mode on its dashboard) takes precedence over evcc; tap Auto to release it. If evcc is removed, delete its claim
(client 262145) in the charger's web UI or via DELETE /claims/262145.
1p/3p phase switching (phases1p3p) only works with modified 3-phase controllers that answer the $G7/$S7 RAPI commands; stock OpenEVSE controllers do not.
Ondersteunde functies
- Ingebouwde meter: Ondersteuning voor een ingebouwde meter.
- Dimbaar: Het opgenomen vermogen kan worden verlaagd (bijv. § 14a EnWG). Zie Externe limiet.
Parameters
| Naam | Omschrijving | Waarde | Niveau |
|---|---|---|---|
host | IP address or hostname | optioneel | |
user | Username e.g. email address, user id, etc. | optioneel | |
password | Password Service account password | optioneel | |
phases1p3p | Phase switching Only for modified 3-phase controllers that support | geavanceerd |
Configuratievoorbeeld voor evcc.yaml
Als u niet via de gebruikersinterface wilt configureren, kunt u ook dit YAML-blok gebruiken.
chargers: - name: my_charger type: template template: openevse host: 192.0.2.2 # IP address or hostname user: # Username, e.g. email address, user id, etc. (optional) password: # Password, Service account password (optional) phases1p3p: # Phase switching, Only for modified 3-phase controllers that support `$G7` and `$S7` (optional)