Ga naar inhoud
slim laden

NIBE Nibe S-Series (SG Ready)

Modbus connection to the NIBE S heat pump. Firmware version 4.7.5 or newer is required. Required settings in the control unit:

  • In the indoor unit, Modbus must be enabled in menu 7.5.9
  • To use power control, “external power limitation via Modbus” must be selected under AUX in menu 7.4. In the charging point settings, a minimum power of 1.2 kW (single-phase) must be configured. If the base load is higher, it must be set as the minimum power.
  • In menu 7.4, the options “SG-Ready A” and “SG-Ready B” must not be assigned.
  • The value 1 (uint8) must be written once to holding register 3032.

Ondersteunde functies

  • Dimbaar: Het opgenomen vermogen kan worden verlaagd (bijv. § 14a EnWG). Zie Externe limiet.

Parameters

NaamOmschrijvingWaardeNiveau
idModbus-ID
Standaard: 1
intverplicht
hostIP-adres of hostnaam
Voorbeeld: 192.0.2.2
verplicht
portPoort
Standaard: 502
intverplicht
tempsourceTemperature sensor
Standaard: water_mid
optioneel
powercontrolpower limitation
Standaard: true
optioneel
Configuratievoorbeeld voor evcc.yaml

Als u niet via de gebruikersinterface wilt configureren, kunt u ook dit YAML-blok gebruiken.

chargers:
- name: my_heating
type: template
template: nibe-s-series
# Modbus TCP
modbus: tcpip
id: 1
host: # Hostname
port: 502 # Port
tempsource: water_mid # Temperature sensor, [water_top, water_mid]
powercontrol: true # power limitation