Alpha ESS Storion SMILE

To use active battery control, times for grid charging must be defined once via the web interface or app. (Settings->Function settings->Grid charging/discharging) A continuous time period should be entered here (e.g.: Charging time 1 00:00-23:00, Charging time 2 23:00-00:00). However, deactivate the "Grid charging" switch. The actual control takes place via evcc. Discharge stop is realized via a scheduled grid charge with a target SoC of 10%. Alternatively, it can also be configured via Modbus. To do this, set the registers 2134,2142,2135,2136,2144,2137,2175 to the values 0,0,23,0,23,0,0,0,0.

Ondersteunde functies

  • Batterijaansturing: Externe aansturing van het laden en ontladen van de thuisbatterij door evcc.

Gebruik

  • Netmeter
  • Zonne-energieproductie
  • Batterij

Parameters

Modbus
NaamOmschrijvingWaardeNiveau
idModbus-ID
Standaard: 1
intverplicht
deviceApparaatnaam

USB-RS485-adapter

Voorbeeld: /dev/ttyUSB0
verplicht
baudrateBaudrate
Standaard: 9600
verplicht
comsetComSet

Communicatieparameter voor de adapter

Standaard: 8N1
verplicht
hostIP-adres of hostnaam
Voorbeeld: 192.0.2.2
verplicht
portPoort
Standaard: 502
intverplicht
capacity [kWh]Battery capacity
Voorbeeld: 50
optioneel
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Standaard: 0
Voorbeeld: 25
optioneel
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and for grid charging.

Standaard: 100
Voorbeeld: 95
optioneel
maxacpower [W]Maximum AC power of the hybrid inverter
Standaard: 0
Voorbeeld: 5000
geavanceerd
maxchargepower [W]Maximum charge power

For forced charging of the battery.

geavanceerd
maxdischargepower [W]Maximum discharge power

Maximum discharge power of the storage.

geavanceerd
Configuratievoorbeeld voor evcc.yaml

Als u niet via de gebruikersinterface wilt configureren, kunt u ook dit YAML-blok gebruiken.

meters:
- name: my_grid
type: template
template: alpha-ess-smile
usage: grid
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 85
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 85
host: # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 85
host: # Hostname
port: 502 # Port
meters:
- name: my_pv
type: template
template: alpha-ess-smile
usage: pv
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 85
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 85
host: # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 85
host: # Hostname
port: 502 # Port
maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optional
meters:
- name: my_battery
type: template
template: alpha-ess-smile
usage: battery
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 85
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 85
host: # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 85
host: # Hostname
port: 502 # Port
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional)
maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional)
maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)