Ga naar inhoud
slim laden

batterX Home

Ondersteunde functies

  • Batterijaansturing: Externe aansturing van het laden en ontladen van de thuisbatterij door evcc.

Gebruik

  • Netmeter
  • Zonne-energieproductie
  • Batterij

Parameters

NaamOmschrijvingWaardeNiveau
hostIP address or hostname
Voorbeeld: 192.0.2.2
optioneel
portPort
Standaard: 80
optioneel
externalpvNeeded when a second solar inverter is connected.

This parameter is needed when the BatterX station is connected to another solar inverter. The total produced solar power can so be reported through one system. Further auxilary solar inverters do not need to be connected to evcc.

Standaard: true
optioneel
capacity [kWh]Battery capacity
Voorbeeld: 50
optioneel
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Standaard: 0
Voorbeeld: 25
optioneel
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and for grid charging.

Standaard: 100
Voorbeeld: 95
optioneel
maxchargepower [W]Maximum charge power

For forced charging of the battery.

geavanceerd
maxdischargepower [W]Maximum discharge power

Maximum discharge power of the storage.

geavanceerd
Configuratievoorbeeld voor evcc.yaml

Als u niet via de gebruikersinterface wilt configureren, kunt u ook dit YAML-blok gebruiken.

meters:
- name: my_grid
type: template
template: batterX
usage: grid
host: 192.0.2.2 # IP address or hostname
port: 80 # Port, optional
externalpv: true # Needed when a second solar inverter is connected., This parameter is needed when the BatterX station is connected to another solar inverter. The total produced solar power can so be reported through one system. Further auxilary solar inverters do not need to be connected to evcc. (optional)
meters:
- name: my_pv
type: template
template: batterX
usage: pv
host: 192.0.2.2 # IP address or hostname
port: 80 # Port, optional
externalpv: true # Needed when a second solar inverter is connected., This parameter is needed when the BatterX station is connected to another solar inverter. The total produced solar power can so be reported through one system. Further auxilary solar inverters do not need to be connected to evcc. (optional)
meters:
- name: my_battery
type: template
template: batterX
usage: battery
host: 192.0.2.2 # IP address or hostname
port: 80 # Port, optional
externalpv: true # Needed when a second solar inverter is connected., This parameter is needed when the BatterX station is connected to another solar inverter. The total produced solar power can so be reported through one system. Further auxilary solar inverters do not need to be connected to evcc. (optional)
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional)
maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional)
maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)