Ga naar inhoud
slim laden

Danfoss TripleLynx TLX/TLX+

Communication uses the RS485 port of the inverter (ComLynx protocol).

Wiring (RJ45 connector on the inverter):

  • Pin 1: GND
  • Pin 2: B (RS485-)
  • Pin 3: A (RS485+)
  • Pin 6: B (daisy-chain to next device)
  • Pin 7: A (daisy-chain to next device)

Termination resistors (120 Ω) are required at both ends of the bus (bridge pins 4→6 and 5→7 on the inverter).

Connect a USB-RS485 adapter (or a network serial bridge) to the RS485 bus. For multiple inverters on one bus set the node parameter for each meter entry.

Gebruik

  • Zonne-energieproductie

Parameters

NaamOmschrijvingWaardeNiveau
deviceSerial port (USB-RS485 adapter)

e.g. /dev/ttyUSB0 — mutually exclusive with uri

Voorbeeld: /dev/ttyUSB0
optioneel
uriTCP endpoint of a network RS485 bridge

e.g. rs485bridge.lan:4196 — mutually exclusive with device

Voorbeeld: localhost:4196
optioneel
nodeInverter node address (hex, N-S-NN)

Only required when multiple inverters share the same RS485 bus. The address is discovered automatically on startup and printed to the log. Format: network-subnet-node in hex, e.g. c-6-b1

Voorbeeld: c-6-b1
geavanceerd
baudrateBaudrate

Typical values are 9600, 19200, 38400, 57600, 115200

Standaard: 19200
geavanceerd
maxacpower [W]Maximum AC power of the hybrid inverter
Standaard: 0
Voorbeeld: 5000
geavanceerd
Configuratievoorbeeld voor evcc.yaml

Als u niet via de gebruikersinterface wilt configureren, kunt u ook dit YAML-blok gebruiken.

meters:
- name: my_pv
type: template
template: danfoss-triplelynx-tlx
usage: pv
device: /dev/ttyUSB0 # Serial port (USB-RS485 adapter), e.g. /dev/ttyUSB0 — mutually exclusive with uri (optional)
uri: localhost:4196 # TCP endpoint of a network RS485 bridge, e.g. rs485bridge.lan:4196 — mutually exclusive with device (optional)
node: c-6-b1 # Inverter node address (hex, N-S-NN), Only required when multiple inverters share the same RS485 bus. The address is discovered automatically on startup and printed to the log. Format: network-subnet-node in hex, e.g. c-6-b1 (optional)
baudrate: 19200 # Baudrate, Typical values are 9600, 19200, 38400, 57600, 115200 (optional)
maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optional