For demonstration purposes. Battery with a fixed set of values.

Gebruik

  • Batterij

Parameters

NaamOmschrijvingWaardeNiveau
power [W]Poweroptioneel
soc [%]Chargeoptioneel
controllableControllable

Supports active battery control

geavanceerd
capacity [kWh]Battery capacity
Voorbeeld: 50
geavanceerd
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Standaard: 0
Voorbeeld: 25
geavanceerd
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and for grid charging.

Standaard: 100
Voorbeeld: 95
geavanceerd
maxchargepower [W]Maximum charge power

For forced charging of the battery.

geavanceerd
maxdischargepower [W]Maximum discharge power

Maximum discharge power of the storage.

geavanceerd
energy [kWh]Meter readinggeavanceerd
currentL1 [A]L1 currentgeavanceerd
currentL2 [A]L2 currentgeavanceerd
currentL3 [A]L3 currentgeavanceerd
maxacpower [W]Maximum AC power of the hybrid inverter
Standaard: 0
Voorbeeld: 5000
geavanceerd
Configuratievoorbeeld voor evcc.yaml

Als u niet via de gebruikersinterface wilt configureren, kunt u ook dit YAML-blok gebruiken.

meters:
- name: my_battery
type: template
template: demo-battery
usage: battery
power: # Power (W), optional
soc: # Charge (%), optional
controllable: # Controllable, Supports active battery control (optional)
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional)
maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional)
maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)
energy: # Meter reading (kWh), optional
currentL1: # L1 current (A), optional
currentL2: # L2 current (A), optional
currentL3: # L3 current (A), optional