Fronius Verto Plus
Meter address of primary or secondary meters: on the web interface of the inverter, only the address of the first meter (e.g., 200) can be set. Additional meters receive an ascending number (e.g., 201).
Ondersteunde functies
- Batterijaansturing: Externe aansturing van het laden en ontladen van de thuisbatterij door evcc.
- Begrensbaar: De productie van de omvormer kan worden verlaagd (bijv. § 9 EEG). Zie Externe limiet.
Gebruik
- Netmeter
- Zonne-energieproductie
- Batterij
Parameters
| Naam | Omschrijving | Waarde | Niveau |
|---|---|---|---|
id | Modbus-ID | int | verplicht |
host | IP-adres of hostnaam | verplicht | |
port | Poort | int | verplicht |
capacity [kWh] | Battery capacity | optioneel | |
minsoc [%] | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | optioneel | |
maxsoc [%] | Maximum charge Upper limit as configured on the battery system. Used by optimizer and for grid charging. | optioneel | |
maxchargerate [%] | Maximum charge rate For forced charging of the battery in percent in relation to the maximum charge power of the battery inverter. | geavanceerd | |
maxchargepower [W] | Maximum charge power For forced charging of the battery. | geavanceerd | |
maxdischargepower [W] | Maximum discharge power Maximum discharge power of the storage. | geavanceerd |
Configuratievoorbeeld voor evcc.yaml
Als u niet via de gebruikersinterface wilt configureren, kunt u ook dit YAML-blok gebruiken.
meters: - name: my_grid type: template template: fronius-vertoplus usage: grid
# Modbus TCP modbus: tcpip id: 200 host: # Hostname port: 502 # Portmeters: - name: my_pv type: template template: fronius-vertoplus usage: pv
# Modbus TCP modbus: tcpip id: 200 host: # Hostname port: 502 # Portmeters: - name: my_battery type: template template: fronius-vertoplus usage: battery
# Modbus TCP modbus: tcpip id: 200 host: # Hostname port: 502 # Port capacity: 50 # Battery capacity (kWh), optional minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional) maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional) maxchargerate: 100 # Maximum charge rate (%), For forced charging of the battery in percent in relation to the maximum charge power of the battery inverter. (optional) maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional) maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)