Ga naar inhoud
slim laden

RCT Power

Ondersteunde functies

  • Batterijaansturing: Externe aansturing van het laden en ontladen van de thuisbatterij door evcc.
  • Begrensbaar: De productie van de omvormer kan worden verlaagd (bijv. § 9 EEG). Zie Externe limiet.

Gebruik

  • Netmeter
  • Zonne-energieproductie
  • Batterij

Parameters

NaamOmschrijvingWaardeNiveau
hostIP address or hostname
Voorbeeld: 192.0.2.2
optioneel
portPort
Standaard: 8899
optioneel
capacity [kWh]Battery capacity
Voorbeeld: 50
optioneel
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Standaard: 7
Voorbeeld: 25
optioneel
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and for grid charging.

Standaard: 97
Voorbeeld: 95
optioneel
capacity2 [kWh]Battery capacity of the second battery
Voorbeeld: 50
optioneel
maxacpower [W]Maximum AC power of the hybrid inverter
Standaard: 0
Voorbeeld: 5000
geavanceerd
externalpowerExternal power

Query external power of all devices connected to S0

geavanceerd
maxchargepower [W]Maximum charge power

For forced charging of the battery.

geavanceerd
maxdischargepower [W]Maximum discharge power

Maximum discharge power of the storage.

geavanceerd
cacheCache

Time interval for data refresh

Standaard: 30s
Voorbeeld: 5m
geavanceerd
Configuratievoorbeeld voor evcc.yaml

Als u niet via de gebruikersinterface wilt configureren, kunt u ook dit YAML-blok gebruiken.

meters:
- name: my_grid
type: template
template: rct-power
usage: grid
host: 192.0.2.2 # IP address or hostname
port: 8899 # Port
cache: 30s # Cache, Time interval for data refresh (optional)
meters:
- name: my_pv
type: template
template: rct-power
usage: pv
host: 192.0.2.2 # IP address or hostname
port: 8899 # Port
maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optional
externalpower: # External power, Query external power of all devices connected to S0 (optional)
cache: 30s # Cache, Time interval for data refresh (optional)
meters:
- name: my_battery
type: template
template: rct-power
usage: battery
host: 192.0.2.2 # IP address or hostname
port: 8899 # Port
capacity: 50 # Battery capacity (kWh), optional
minsoc: 7 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 97 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional)
capacity2: 50 # Battery capacity of the second battery (kWh), optional
maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional)
maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)
cache: 30s # Cache, Time interval for data refresh (optional)