SofarSolar SOFAR 5…24KTL-G3
For more details on how to establish a connection to the inverter see the Sofar Solar installation doc at homeassistant-solax-modbus.readthedocs.io.
Ondersteunde functies
- Batterijaansturing: Externe aansturing van het laden en ontladen van de thuisbatterij door evcc.
Gebruik
- Netmeter
- Zonne-energieproductie
- Batterij
Parameters
| Naam | Omschrijving | Waarde | Niveau |
|---|---|---|---|
id | Modbus-ID | int | verplicht |
device | Apparaatnaam USB-RS485-adapter | verplicht | |
baudrate | Baudrate | verplicht | |
comset | ComSet Communicatieparameter voor de adapter | verplicht | |
host | IP-adres of hostnaam | verplicht | |
port | Poort | int | verplicht |
capacity [kWh] | Battery capacity | optioneel | |
minsoc [%] | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | optioneel | |
maxsoc [%] | Maximum charge Upper limit as configured on the battery system. Used by optimizer and for grid charging. | optioneel | |
maxacpower [W] | Maximum AC power of the hybrid inverter | geavanceerd | |
storageunit | Battery storage unit index In case of a BTS storage not the address of a BTS 5K battery module, but the storage tower (BTS 5K-BDU control unit with 1-4 BTS 5K modules). | geavanceerd | |
defaultmode | Default mode for battery control Valid values are 0 (self use), 1 (time of use), 2 (timing mode), 4 (peak-shaving mode) | geavanceerd | |
externalpower | Include external power Includes all connected external sources, like the power generation of cascaded inverters, into the PV power calculation. | geavanceerd | |
maxchargepower [W] | Maximum charge power For forced charging of the battery. | geavanceerd | |
maxdischargepower [W] | Maximum discharge power Maximum discharge power of the storage. | geavanceerd |
Configuratievoorbeeld voor evcc.yaml
Als u niet via de gebruikersinterface wilt configureren, kunt u ook dit YAML-blok gebruiken.
meters: - name: my_grid type: template template: sofarsolar-g3 usage: grid
# RS485 via adapter (Modbus RTU) modbus: rs485serial id: 1 device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200 comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU) modbus: rs485tcpip id: 1 host: # Hostname port: 8899 # Port
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 8899 # Portmeters: - name: my_pv type: template template: sofarsolar-g3 usage: pv
# RS485 via adapter (Modbus RTU) modbus: rs485serial id: 1 device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200 comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU) modbus: rs485tcpip id: 1 host: # Hostname port: 8899 # Port
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 8899 # Port maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optional externalpower: # Include external power, Includes all connected external sources, like the power generation of cascaded inverters, into the PV power calculation. (optional)meters: - name: my_battery type: template template: sofarsolar-g3 usage: battery
# RS485 via adapter (Modbus RTU) modbus: rs485serial id: 1 device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200 comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU) modbus: rs485tcpip id: 1 host: # Hostname port: 8899 # Port
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 8899 # Port capacity: 50 # Battery capacity (kWh), optional minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional) maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional) storageunit: 1 # Battery storage unit index, In case of a BTS storage not the address of a BTS 5K battery module, but the storage tower (BTS 5K-BDU control unit with 1-4 BTS 5K modules). (optional) defaultmode: 0 # Default mode for battery control, Valid values are 0 (self use), 1 (time of use), 2 (timing mode), 4 (peak-shaving mode) (optional) maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional) maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)