Ga naar inhoud
slim laden

Solax Hybrid-Inverter (Cloud)

The Solax hybrid inverter has to be registered in the SolaxCloud.

Attention: Values can only be fetched every 150s and then also can be 5 minutes old. Charging by PV will not be optimal because of this! Only use as fallback if no local access is available.

Gebruik

  • Netmeter
  • Zonne-energieproductie
  • Batterij

Parameters

NaamOmschrijvingWaardeNiveau
tokenidSolaxCloud TokenID

solaxcloud.com -> Support -> Third-party Ecology (old site) or Service -> API (new site), enter the value of tokenID here (Example: 20241028488283838)

optioneel
serialSerial number

solaxcloud.com -> Device -> Inverter (new site) or Support (old site), use the registration number

optioneel
capacity [kWh]Battery capacity
Voorbeeld: 50
optioneel
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Standaard: 0
Voorbeeld: 25
optioneel
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and for grid charging.

Standaard: 100
Voorbeeld: 95
optioneel
maxchargepower [W]Maximum charge power

For forced charging of the battery.

geavanceerd
maxdischargepower [W]Maximum discharge power

Maximum discharge power of the storage.

geavanceerd
cacheCache

Time interval for data refresh

Standaard: 1s
Voorbeeld: 5m
geavanceerd
Configuratievoorbeeld voor evcc.yaml

Als u niet via de gebruikersinterface wilt configureren, kunt u ook dit YAML-blok gebruiken.

meters:
- name: my_grid
type: template
template: solax-hybrid-cloud
usage: grid
tokenid: # SolaxCloud TokenID, [solaxcloud.com](https://www.solaxcloud.com/) -> Support -> Third-party Ecology (old site) or Service -> API (new site), enter the value of `tokenID` here (Example: 20241028488283838)
serial: # Serial number, [solaxcloud.com](https://www.solaxcloud.com/) -> Device -> Inverter (new site) or Support (old site), use the registration number
cache: 1s # Cache, Time interval for data refresh (optional)
meters:
- name: my_pv
type: template
template: solax-hybrid-cloud
usage: pv
tokenid: # SolaxCloud TokenID, [solaxcloud.com](https://www.solaxcloud.com/) -> Support -> Third-party Ecology (old site) or Service -> API (new site), enter the value of `tokenID` here (Example: 20241028488283838)
serial: # Serial number, [solaxcloud.com](https://www.solaxcloud.com/) -> Device -> Inverter (new site) or Support (old site), use the registration number
cache: 1s # Cache, Time interval for data refresh (optional)
meters:
- name: my_battery
type: template
template: solax-hybrid-cloud
usage: battery
tokenid: # SolaxCloud TokenID, [solaxcloud.com](https://www.solaxcloud.com/) -> Support -> Third-party Ecology (old site) or Service -> API (new site), enter the value of `tokenID` here (Example: 20241028488283838)
serial: # Serial number, [solaxcloud.com](https://www.solaxcloud.com/) -> Device -> Inverter (new site) or Support (old site), use the registration number
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional)
maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional)
maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)
cache: 1s # Cache, Time interval for data refresh (optional)