Ga naar inhoud
slim laden

VARTA element backup

PV is only available with an additional PV sensor, as the power of the devices registered in the SUNSPEC Manager is not output via Modbus. Element backup requires at least firmware version F21000612. The firmware update is not rolled out automatically, but can be released upon request by VARTA's technical service.

Gebruik

  • Netmeter
  • Zonne-energieproductie
  • Batterij

Parameters

NaamOmschrijvingWaardeNiveau
idModbus-ID
Standaard: 1
intverplicht
hostIP-adres of hostnaam
Voorbeeld: 192.0.2.2
verplicht
portPoort
Standaard: 502
intverplicht
capacity [kWh]Battery capacity
Voorbeeld: 50
optioneel
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Standaard: 0
Voorbeeld: 25
optioneel
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and for grid charging.

Standaard: 100
Voorbeeld: 95
optioneel
maxchargepower [W]Maximum charge power

For forced charging of the battery.

geavanceerd
maxdischargepower [W]Maximum discharge power

Maximum discharge power of the storage.

Standaard: 4000
geavanceerd
watchdogWatchdog
Standaard: 120s
geavanceerd
Configuratievoorbeeld voor evcc.yaml

Als u niet via de gebruikersinterface wilt configureren, kunt u ook dit YAML-blok gebruiken.

meters:
- name: my_grid
type: template
template: varta
usage: grid
# Modbus TCP
modbus: tcpip
id: 255
host: # Hostname
port: 502 # Port
meters:
- name: my_pv
type: template
template: varta
usage: pv
# Modbus TCP
modbus: tcpip
id: 255
host: # Hostname
port: 502 # Port
meters:
- name: my_battery
type: template
template: varta
usage: battery
# Modbus TCP
modbus: tcpip
id: 255
host: # Hostname
port: 502 # Port
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional)
maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional)
maxdischargepower: 4000 # Maximum discharge power (W), Maximum discharge power of the storage. (optional)
watchdog: 120s # Watchdog, optional