slim laden

Mennekes AMTRON Professional Twincharge PnC

Deze pagina toont de nightly-versie. Schakel over naar de releaseversie.

The 'Modbus TCP Server' must be enabled. The setting 'Register Address Set' must NOT be set to 'Phoenix' or 'TQ-DM100'. Use the third selection labeled 'Ebee', 'Bender', 'MENNEKES' etc. Set 'Allow UID Disclose' to On.

Firmware 5.33 or higher is required for phase switching (if supported by the model). The 'SEMP interface' must be enabled, the 'SEMP Charging Mode' must be set to 'Surplus Charging'. Set 'Software function to use phase switching' to SEMP.

For charging stations with two charging points (e.g. AMEDIO, Twincharge), each charging point must be configured separately. Set charging point 1 to Port 502 and charging point 2 to Port 503.

Ondersteunde functies

  • Ingebouwde meter: Ondersteuning voor een ingebouwde meter.
  • ISO 15118-2: Plug & Charge (voertuigherkenning, overdracht van het laadniveau).
  • RFID: Geïntegreerde RFID-kaartlezer voor voertuigherkenning.
  • Dimbaar: Het opgenomen vermogen kan worden verlaagd (bijv. § 14a EnWG). Zie Externe limiet.

Parameters

NaamOmschrijvingWaardeNiveau
idModbus-ID
Standaard: 1
intverplicht
hostIP-adres of hostnaam
Voorbeeld: 192.0.2.2
verplicht
portPoort
Standaard: 502
intverplicht
Configuratievoorbeeld voor evcc.yaml

Als u niet via de gebruikersinterface wilt configureren, kunt u ook dit YAML-blok gebruiken.

chargers:
- name: my_charger
type: template
template: bender-cc
# Modbus TCP
modbus: tcpip
id: 255
host: # Hostname
port: 502 # Port