SMA eCharger (SEMP)
Configure the SEMP base URL (http://<charger-host>/SEMP) and the device ID of the charger.
IMPORTANT: The charger must NOT be registered directly as a consumer in the Sunny Home Manager / Sunny Portal at the same time!
Setup on the "SMA EV Charger":
- Set the rotary switch on the wallbox to PV/Eco charging.
- Deactivate the wallbox in the Sunny Portal (it can be added back via evcc later).
- Set "Operation with grid connection point meter" to "Yes" and set up a meter (SMA Sunny Home Manager 2 or Energy Meter) under "Configuration -> Parameters -> Meter configuration". This is required for the SEMP interface to be enabled.
- Set "Charging release via app" to "No".
- Set "Disconnect after full charge" to "No".
- Restart the device and wait for it to come back online.
- Add the charger in evcc and check/save the configuration (a vehicle may need to be connected for the SEMP interface to report the correct status).
Ondersteunde functies
- mA-regeling: Fijnere regeling van de laadstroom (mA in plaats van A) voor beter gebruik van het zonneoverschot.
- 1P/3P: Automatische faseomschakeling. Handig voor laden met zonneoverschot.
- Ingebouwde meter: Ondersteuning voor een ingebouwde meter.
- Dimbaar: Het opgenomen vermogen kan worden verlaagd (bijv. § 14a EnWG). Zie Externe limiet.
Parameters
| Naam | Omschrijving | Waarde | Niveau |
|---|---|---|---|
uri | SEMP base URL HTTP(S) address | optioneel |
Configuratievoorbeeld voor evcc.yaml
Als u niet via de gebruikersinterface wilt configureren, kunt u ook dit YAML-blok gebruiken.
chargers: - name: my_charger type: template template: semp-sma uri: http://192.168.178.100/SEMP # SEMP base URL, HTTP(S) address