Connect the relay contacts of the control box to the inputs SW1 to SW3. With three inputs only the feed-in limitation (W3, S1, S2) is mapped by default. Dimming of controllable loads (W4) requires reassigning one of the inputs.

Parameters

NaamOmschrijvingWaardeNiveau
hostIP address or hostname
Voorbeeld: 192.0.2.2
optioneel
w3inputW3 input

Input number for the W3 signal (Zero export, 0%), 1 to 3 (SW1 = 1)

Standaard: 1
optioneel
userUsername

Only required if authentication is enabled on the device

optioneel
passwordPassword

Service account password

optioneel
productionnominalmax [Wp]Installed generator power

Rated generator/module power of the installation (reference value according to § 9 EEG).

optioneel
s1inputS1 input

Input number for the S1 signal (60% export power limit), 1 to 3 (SW1 = 1)

Standaard: 2
optioneel
s2inputS2 input

Input number for the S2 signal (30% export power limit), 1 to 3 (SW1 = 1)

Standaard: 3
optioneel
w4inputW4 input

Input number for the W4 signal (Dimmer for controllable loads), 1 to 3 (SW1 = 1). Not mapped by default.

geavanceerd
maxconsumptionpower [W]Guaranteed minimum power (Pmin)

Power limit applied to the root circuit while the limit is active. Required if W4 is mapped.

geavanceerd
Configuratievoorbeeld voor evcc.yaml

Als u niet via de gebruikersinterface wilt configureren, kunt u ook dit YAML-blok gebruiken.

hems:
type: template
template: fnn-shelly-i3
host: 192.0.2.2 # IP address or hostname
w3input: 1 # W3 input, Input number for the W3 signal (Zero export, 0%), 1 to 3 (SW1 = 1)
user: # Username, Only required if authentication is enabled on the device (optional)
password: # Password, Service account password (optional)
productionnominalmax: # Installed generator power (Wp), Rated generator/module power of the installation (reference value according to § 9 EEG). (optional)
s1input: 2 # S1 input, Input number for the S1 signal (60% export power limit), 1 to 3 (SW1 = 1) (optional)
s2input: 3 # S2 input, Input number for the S2 signal (30% export power limit), 1 to 3 (SW1 = 1) (optional)
w4input: # W4 input, Input number for the W4 signal (Dimmer for controllable loads), 1 to 3 (SW1 = 1). Not mapped by default. (optional)
maxconsumptionpower: # Guaranteed minimum power (Pmin) (W), Power limit applied to the root circuit while the limit is active. Required if W4 is mapped. (optional)