Use the local web interface of AC•THOR to set the value "Power timeout" to a value slightly higher (e.g. + 5s) than the interval time of evcc. Use control type "Modbus TCP" and set loadpoint minimal current to 0.125A. If the heating element at the controlled output has < 9 kW, the scaling factor has to be calculated as follows: scale = 9000 / nominal power of the connected heater.

Operation mode M3: 9 + 9 kW with an additional heater connected to the relay output is supported. Without load measurement using my-PV meter, the "Load at relay" setting in the local web interface of the AC•THOR must be set to match the nominal power of the heating element at the relay. If the heater at the controlled output has < 9 kW, AC•THOR firmware a0022401 or higher is required and the value for "Load at relay" must be converted using the scaling factor as follows: Load at relay = nominal power of the heater at the relay * scale factor

Ondersteunde functies

  • Ingebouwde meter: Ondersteuning voor een ingebouwde meter.

Parameters

NaamOmschrijvingWaardeNiveau
idModbus-ID
Standaard: 1
intverplicht
hostIP-adres of hostnaam
Voorbeeld: 192.0.2.2
verplicht
portPoort
Standaard: 502
intverplicht
tempsourceTemperature source
Standaard: 1
optioneel
scaleScale factor for power target value
Standaard: 1
optioneel
Configuratievoorbeeld voor evcc.yaml

Als u niet via de gebruikersinterface wilt configureren, kunt u ook dit YAML-blok gebruiken.

chargers:
- name: my_heating
type: template
template: ac-thor
# Modbus TCP
modbus: tcpip
id: 1
host: # Hostname
port: 502 # Port
tempsource: 1 # Temperature source, [1, 2, 3] (optional)
scale: 1 # Scale factor for power target value, optional