A-Tronix AX Plus Hybrid Inverter
Ondersteunde functies
- Batterijaansturing: Externe aansturing van het laden en ontladen van de thuisbatterij door evcc.
Gebruik
- Netmeter
- Zonne-energieproductie
- Batterij
Parameters
| Naam | Omschrijving | Waarde | Niveau |
|---|---|---|---|
id | Modbus-ID | int | verplicht |
device | Apparaatnaam USB-RS485-adapter | verplicht | |
baudrate | Baudrate | verplicht | |
comset | ComSet Communicatieparameter voor de adapter | verplicht | |
host | IP-adres of hostnaam | verplicht | |
port | Poort | int | verplicht |
maxchargepower [W] | Maximum charge power Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. | optioneel | |
maxdischargecurrent | Max Discharge Current Battery max discharge current in A, written back when leaving hold mode. Inverter default is 50 A for H3-Pro/Smart (26 A for H3). | optioneel | |
capacity [kWh] | Battery capacity | optioneel | |
minsoc [%] | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | optioneel | |
maxsoc [%] | Maximum charge Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. | optioneel | |
maxchargecurrent | Max Charge Current Battery max charge current in A, written back when leaving holdcharge mode. Inverter default is 50 A for H3-Pro/Smart. | optioneel | |
maxacpower [W] | Maximum AC power of the hybrid inverter | geavanceerd | |
maxdischargepower [W] | Maximum discharge power Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. | geavanceerd |
Configuratievoorbeeld voor evcc.yaml
Als u niet via de gebruikersinterface wilt configureren, kunt u ook dit YAML-blok gebruiken.
meters: - name: my_grid type: template template: fox-ess-h3-smart usage: grid
# RS485 via adapter (Modbus RTU) modbus: rs485serial id: 247 device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200 comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU) modbus: rs485tcpip id: 247 host: # Hostname port: 502 # Port
# Modbus TCP modbus: tcpip id: 247 host: # Hostname port: 502 # Port maxdischargecurrent: # Max Discharge Current, Battery max discharge current in A, written back when leaving hold mode. Inverter default is 50 A for H3-Pro/Smart (26 A for H3). maxchargecurrent: 50 # Max Charge Current, Battery max charge current in A, written back when leaving holdcharge mode. Inverter default is 50 A for H3-Pro/Smart. (optional)meters: - name: my_pv type: template template: fox-ess-h3-smart usage: pv
# RS485 via adapter (Modbus RTU) modbus: rs485serial id: 247 device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200 comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU) modbus: rs485tcpip id: 247 host: # Hostname port: 502 # Port
# Modbus TCP modbus: tcpip id: 247 host: # Hostname port: 502 # Port maxdischargecurrent: # Max Discharge Current, Battery max discharge current in A, written back when leaving hold mode. Inverter default is 50 A for H3-Pro/Smart (26 A for H3). maxchargecurrent: 50 # Max Charge Current, Battery max charge current in A, written back when leaving holdcharge mode. Inverter default is 50 A for H3-Pro/Smart. (optional) maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optionalmeters: - name: my_battery type: template template: fox-ess-h3-smart usage: battery
# RS485 via adapter (Modbus RTU) modbus: rs485serial id: 247 device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200 comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU) modbus: rs485tcpip id: 247 host: # Hostname port: 502 # Port
# Modbus TCP modbus: tcpip id: 247 host: # Hostname port: 502 # Port maxchargepower: # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. maxdischargecurrent: # Max Discharge Current, Battery max discharge current in A, written back when leaving hold mode. Inverter default is 50 A for H3-Pro/Smart (26 A for H3). capacity: 50 # Battery capacity (kWh), optional minsoc: 10 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional) maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional) maxchargecurrent: 50 # Max Charge Current, Battery max charge current in A, written back when leaving holdcharge mode. Inverter default is 50 A for H3-Pro/Smart. (optional) maxdischargepower: # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. (optional)