Fronius Solar API V1
Solar API should only be used as fallback. Integration via Modbus is preferred.
Username and password are only required for active battery control.
Attention: Active battery control should only be used if no other settings for time-dependent battery control were made in the inverter configuration under "Energy Management" - "Battery Management", as existing settings will be overwritten. Choose corresponding configuration URI!
Ondersteunde functies
- Batterijaansturing: Externe aansturing van het laden en ontladen van de thuisbatterij door evcc.
Gebruik
- Netmeter
- Zonne-energieproductie
- Batterij
Parameters
| Naam | Omschrijving | Waarde | Niveau |
|---|---|---|---|
host | IP address or hostname | optioneel | |
user | Username (for active battery control) e.g. email address, user id, etc. | optioneel | |
password | Password (for active battery control) Service account password | optioneel | |
capacity [kWh] | Battery capacity | optioneel | |
minsoc [%] | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | optioneel | |
maxsoc [%] | Maximum charge Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. | optioneel | |
batteryconfiguri | Battery configuration URI Firmware starting with 1.36.5-1 requires /api/config. | geavanceerd | |
maxchargepower [W] | Maximum charge power Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. | geavanceerd | |
maxdischargepower [W] | Maximum discharge power Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. | geavanceerd | |
cache | Cache Time interval for data refresh | geavanceerd |
Configuratievoorbeeld voor evcc.yaml
Als u niet via de gebruikersinterface wilt configureren, kunt u ook dit YAML-blok gebruiken.
meters: - name: my_grid type: template template: fronius-solarapi-v1 usage: grid host: 192.0.2.2 # IP address or hostname user: customer # Username (for active battery control), e.g. email address, user id, etc. (optional) password: # Password (for active battery control), Service account password (optional) batteryconfiguri: /config # Battery configuration URI, Firmware starting with 1.36.5-1 requires /api/config. [/config, /api/config] (optional) cache: 1s # Cache, Time interval for data refresh (optional)meters: - name: my_pv type: template template: fronius-solarapi-v1 usage: pv host: 192.0.2.2 # IP address or hostname user: customer # Username (for active battery control), e.g. email address, user id, etc. (optional) password: # Password (for active battery control), Service account password (optional) batteryconfiguri: /config # Battery configuration URI, Firmware starting with 1.36.5-1 requires /api/config. [/config, /api/config] (optional) cache: 1s # Cache, Time interval for data refresh (optional)meters: - name: my_battery type: template template: fronius-solarapi-v1 usage: battery host: 192.0.2.2 # IP address or hostname user: customer # Username (for active battery control), e.g. email address, user id, etc. (optional) password: # Password (for active battery control), Service account password (optional) capacity: 50 # Battery capacity (kWh), optional minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional) maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional) batteryconfiguri: /config # Battery configuration URI, Firmware starting with 1.36.5-1 requires /api/config. [/config, /api/config] (optional) maxchargepower: # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. (optional) maxdischargepower: # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. (optional) cache: 1s # Cache, Time interval for data refresh (optional)