Huawei SmartLogger
Ondersteunde functies
- Batterijaansturing: Externe aansturing van het laden en ontladen van de thuisbatterij door evcc.
- Begrensbaar: De productie van de omvormer kan worden verlaagd (bijv. § 9 EEG). Zie Externe limiet.
Gebruik
- Netmeter
- Zonne-energieproductie
- Batterij
Parameters
| Naam | Omschrijving | Waarde | Niveau |
|---|---|---|---|
id | Modbus-ID | int | verplicht |
host | IP-adres of hostnaam | verplicht | |
port | Poort | int | verplicht |
capacity [kWh] | Battery capacity | optioneel | |
minsoc [%] | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | optioneel | |
maxsoc [%] | Maximum charge Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. | optioneel | |
maxacpower [W] | Maximum AC power of the hybrid inverter | geavanceerd | |
storageunit | Battery storage unit index | geavanceerd | |
maxchargepower [W] | Maximum charge power Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. | geavanceerd | |
maxdischargepower [W] | Maximum discharge power Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. | geavanceerd |
Configuratievoorbeeld voor evcc.yaml
Als u niet via de gebruikersinterface wilt configureren, kunt u ook dit YAML-blok gebruiken.
meters: - name: my_grid type: template template: huawei-smartlogger usage: grid
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 502 # Portmeters: - name: my_pv type: template template: huawei-smartlogger usage: pv
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 502 # Port maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optionalmeters: - name: my_battery type: template template: huawei-smartlogger usage: battery
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 502 # Port capacity: 50 # Battery capacity (kWh), optional minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional) maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional) storageunit: 1 # Battery storage unit index, optional maxchargepower: # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. (optional) maxdischargepower: # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. (optional)