Ga naar inhoud
slim laden

KACO blueplanet hybrid NH3

Deze pagina toont de nightly-versie. Er is nog geen releaseversie.

For KACO blueplanet Hybrid NH3 with AI dongle/Wi-Fi stick. Modbus TCP and the local AISWEI HTTP API must be reachable at the stick's IP address (Modbus TCP port 502, device ID 3; HTTP port 8484). Battery power control uses the local fdbg.cgi endpoint. Maximum charge and discharge power are read from SunSpec Model 802. Battery charge and discharge energy are read from the local AISWEI HTTP API. Configure curtailment through a separate KACO NH3 curtailer device. The grid meter exposed through SunSpec Model 203 provides grid power, import/export energy, and per-phase measurements.

Ondersteunde functies

  • Batterijaansturing: Externe aansturing van het laden en ontladen van de thuisbatterij door evcc.

Gebruik

  • Netmeter
  • Zonne-energieproductie
  • Batterij

Parameters

NaamOmschrijvingWaardeNiveau
idModbus-ID
Standaard: 1
intverplicht
hostIP-adres of hostnaam
Voorbeeld: 192.0.2.2
verplicht
portPoort
Standaard: 502
intverplicht
batteryBattery numberoptioneel
serialInverter serial number (isn)optioneel
capacity [kWh]Battery capacity
Voorbeeld: 50
optioneel
minsoc [%]Minimum charge

Written to the inverter as the discharge limit and used by the optimizer. Only set a value supported by the battery. Minimum value is 5%.

Standaard: 10
Voorbeeld: 25
optioneel
maxsoc [%]Maximum charge

Written to the inverter as the charge limit and used by the optimizer. Only set a value supported by the battery.

Standaard: 100
Voorbeeld: 95
optioneel
Configuratievoorbeeld voor evcc.yaml

Als u niet via de gebruikersinterface wilt configureren, kunt u ook dit YAML-blok gebruiken.

meters:
- name: my_grid
type: template
template: kaco-nh3
usage: grid
# Modbus TCP
modbus: tcpip
id: 3
host: # Hostname
port: 502 # Port
meters:
- name: my_pv
type: template
template: kaco-nh3
usage: pv
# Modbus TCP
modbus: tcpip
id: 3
host: # Hostname
port: 502 # Port
meters:
- name: my_battery
type: template
template: kaco-nh3
usage: battery
# Modbus TCP
modbus: tcpip
id: 3
host: # Hostname
port: 502 # Port
battery: # Battery number, [1, 2]
serial: # Inverter serial number (isn)
capacity: 50 # Battery capacity (kWh), optional
minsoc: 10 # Minimum charge (%), Written to the inverter as the discharge limit and used by the optimizer. Only set a value supported by the battery. Minimum value is 5%. (optional)
maxsoc: 100 # Maximum charge (%), Written to the inverter as the charge limit and used by the optimizer. Only set a value supported by the battery. (optional)