Ga naar inhoud
slim laden

SENEC .Home

Deze pagina toont de nightly-versie. Schakel over naar de releaseversie.

Battery control only includes grid charging, not the discharge lock. The SENEC.Home P4 is not supported.

Ondersteunde functies

  • Batterijaansturing: Externe aansturing van het laden en ontladen van de thuisbatterij door evcc.

Gebruik

  • Netmeter
  • Zonne-energieproductie
  • Batterij

Parameters

NaamOmschrijvingWaardeNiveau
hostIP address or hostname
Voorbeeld: 192.0.2.2
optioneel
schemaSchema
Standaard: https
optioneel
capacity [kWh]Battery capacity
Voorbeeld: 50
optioneel
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Standaard: 0
Voorbeeld: 25
optioneel
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging.

Standaard: 100
Voorbeeld: 95
optioneel
maxchargepower [W]Maximum charge power

Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power.

geavanceerd
maxdischargepower [W]Maximum discharge power

Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging.

geavanceerd
Configuratievoorbeeld voor evcc.yaml

Als u niet via de gebruikersinterface wilt configureren, kunt u ook dit YAML-blok gebruiken.

meters:
- name: my_grid
type: template
template: senec-home
usage: grid
host: 192.0.2.2 # IP address or hostname
schema: https # Schema, [https, http] (optional)
meters:
- name: my_pv
type: template
template: senec-home
usage: pv
host: 192.0.2.2 # IP address or hostname
schema: https # Schema, [https, http] (optional)
meters:
- name: my_battery
type: template
template: senec-home
usage: battery
host: 192.0.2.2 # IP address or hostname
schema: https # Schema, [https, http] (optional)
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional)
maxchargepower: # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. (optional)
maxdischargepower: # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. (optional)