Solakon ONE
Ondersteunde functies
- Batterijaansturing: Externe aansturing van het laden en ontladen van de thuisbatterij door evcc.
Gebruik
- Netmeter
- Zonne-energieproductie
- Batterij
Parameters
Modbus
| Naam | Omschrijving | Waarde | Niveau |
|---|---|---|---|
id | Modbus-ID | int | verplicht |
device | Apparaatnaam USB-RS485-adapter | verplicht | |
baudrate | Baudrate | verplicht | |
comset | ComSet Communicatieparameter voor de adapter | verplicht | |
host | IP-adres of hostnaam | verplicht | |
port | Poort | int | verplicht |
minsoc [%] | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | optioneel | |
maxsoc [%] | Maximum charge Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. | optioneel | |
maxchargepower [W] | Maximum charge power Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. | optioneel | |
maxdischargepower [W] | Maximum discharge power Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. | optioneel | |
capacity [kWh] | Battery capacity | optioneel | |
maxacpower [W] | Maximum AC power of the hybrid inverter | geavanceerd |
Configuratievoorbeeld voor evcc.yaml
Als u niet via de gebruikersinterface wilt configureren, kunt u ook dit YAML-blok gebruiken.
meters: - name: my_grid type: template template: fox-ess-avocado usage: grid
# RS485 via adapter (Modbus RTU) modbus: rs485serial id: 1 device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200 comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU) modbus: rs485tcpip id: 1 host: # Hostname port: 502 # Port
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 502 # Portmeters: - name: my_pv type: template template: fox-ess-avocado usage: pv
# RS485 via adapter (Modbus RTU) modbus: rs485serial id: 1 device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200 comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU) modbus: rs485tcpip id: 1 host: # Hostname port: 502 # Port
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 502 # Port maxacpower: 800 # Maximum AC power of the hybrid inverter (W), optionalmeters: - name: my_battery type: template template: fox-ess-avocado usage: battery
# RS485 via adapter (Modbus RTU) modbus: rs485serial id: 1 device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200 comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU) modbus: rs485tcpip id: 1 host: # Hostname port: 502 # Port
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 502 # Port minsoc: 10 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. maxchargepower: 1200 # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. maxdischargepower: 800 # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. capacity: 2.11 # Battery capacity (kWh), optional