Victron Energy
For grid usage, a grid meter VRM instance is require to enabled load management.
Ondersteunde functies
- Batterijaansturing: Externe aansturing van het laden en ontladen van de thuisbatterij door evcc.
Gebruik
- Netmeter
- Zonne-energieproductie
- Batterij
Parameters
| Naam | Omschrijving | Waarde | Niveau |
|---|---|---|---|
id | Modbus-ID | int | verplicht |
host | IP-adres of hostnaam | verplicht | |
port | Poort | int | verplicht |
meterid | Grid meter VRM instance Can be read out in VRM portal or via remoteUI. | optioneel | |
capacity [kWh] | Battery capacity | optioneel | |
minsoc [%] | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | optioneel | |
maxsoc [%] | Maximum charge Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. | optioneel | |
maxacpower [W] | Maximum AC power of the hybrid inverter | geavanceerd | |
maxchargepower [W] | Maximum charge power Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. | geavanceerd | |
maxdischargepower [W] | Maximum discharge power Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. | geavanceerd |
Configuratievoorbeeld voor evcc.yaml
Als u niet via de gebruikersinterface wilt configureren, kunt u ook dit YAML-blok gebruiken.
meters: - name: my_grid type: template template: victron-energy usage: grid
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 502 # Port meterid: # Grid meter VRM instance, Can be read out in VRM portal or via remoteUI. (optional)meters: - name: my_pv type: template template: victron-energy usage: pv
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 502 # Port maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optionalmeters: - name: my_battery type: template template: victron-energy usage: battery
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 502 # Port capacity: 50 # Battery capacity (kWh), optional minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional) maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional) maxchargepower: # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. (optional) maxdischargepower: # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. (optional)