Zendure Hyper 2000
Gebruik
- Zonne-energieproductie
- Batterij
Parameters
| Naam | Omschrijving | Waarde | Niveau |
|---|---|---|---|
account | Account ID | optioneel | |
serial | Serial You can find this in the Zendure App in the settings of the device | optioneel | |
region | Region | optioneel | |
minsoc [%] | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | optioneel | |
maxsoc [%] | Maximum charge Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. | optioneel | |
timeout | Timeout | optioneel | |
capacity [kWh] | Battery capacity | geavanceerd | |
maxchargepower [W] | Maximum charge power Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. | geavanceerd | |
maxdischargepower [W] | Maximum discharge power Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. | geavanceerd |
Configuratievoorbeeld voor evcc.yaml
Als u niet via de gebruikersinterface wilt configureren, kunt u ook dit YAML-blok gebruiken.
meters: - name: my_pv type: template template: zendure-hyper usage: pv account: dev@zendure.com # Account ID serial: VU5D99F74021B04 # Serial, You can find this in the Zendure App in the settings of the device region: EU # Region, [EU, Global] timeout: 10s # Timeout, optionalmeters: - name: my_battery type: template template: zendure-hyper usage: battery account: dev@zendure.com # Account ID serial: VU5D99F74021B04 # Serial, You can find this in the Zendure App in the settings of the device region: EU # Region, [EU, Global] minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional) maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and, on some devices, for grid charging. (optional) timeout: 10s # Timeout, optional capacity: 2 # Battery capacity (kWh), optional maxchargepower: 1200 # Maximum charge power (W), Highest power the battery system can charge with. The optimizer plans with charging up to this power. Some devices also use it as grid charging power. (optional) maxdischargepower: 800 # Maximum discharge power (W), Highest power the battery system can discharge with. The optimizer plans with discharging up to this power. Smart mode assumes the battery supplies at most this power to vehicle charging. (optional)