Shelly i3

Connect the relay contacts of the control box to the inputs SW1 to SW3. With three inputs only the feed-in limitation (W3, S1, S2) is mapped by default. Dimming of controllable loads (W4) requires reassigning one of the inputs.

Parametri

NomeDescrizioneValoreLivello
hostIP address or hostname
Esempio: 192.0.2.2
facoltativo
w3inputW3 input

Input number for the W3 signal (Zero export, 0%), 1 to 3 (SW1 = 1)

Predefinito: 1
facoltativo
userUsername

Only required if authentication is enabled on the device

facoltativo
passwordPassword

Service account password

facoltativo
productionnominalmax [Wp]Installed generator power

Rated generator/module power of the installation (reference value according to § 9 EEG).

facoltativo
s1inputS1 input

Input number for the S1 signal (60% export power limit), 1 to 3 (SW1 = 1)

Predefinito: 2
facoltativo
s2inputS2 input

Input number for the S2 signal (30% export power limit), 1 to 3 (SW1 = 1)

Predefinito: 3
facoltativo
w4inputW4 input

Input number for the W4 signal (Dimmer for controllable loads), 1 to 3 (SW1 = 1). Not mapped by default.

avanzato
maxconsumptionpower [W]Guaranteed minimum power (Pmin)

Power limit applied to the root circuit while the limit is active. Required if W4 is mapped.

avanzato
Esempio di configurazione per evcc.yaml

Se preferisci non configurare il dispositivo dall’interfaccia, puoi usare questo blocco YAML.

hems:
type: template
template: fnn-shelly-i3
host: 192.0.2.2 # IP address or hostname
w3input: 1 # W3 input, Input number for the W3 signal (Zero export, 0%), 1 to 3 (SW1 = 1)
user: # Username, Only required if authentication is enabled on the device (optional)
password: # Password, Service account password (optional)
productionnominalmax: # Installed generator power (Wp), Rated generator/module power of the installation (reference value according to § 9 EEG). (optional)
s1input: 2 # S1 input, Input number for the S1 signal (60% export power limit), 1 to 3 (SW1 = 1) (optional)
s2input: 3 # S2 input, Input number for the S2 signal (30% export power limit), 1 to 3 (SW1 = 1) (optional)
w4input: # W4 input, Input number for the W4 signal (Dimmer for controllable loads), 1 to 3 (SW1 = 1). Not mapped by default. (optional)
maxconsumptionpower: # Guaranteed minimum power (Pmin) (W), Power limit applied to the root circuit while the limit is active. Required if W4 is mapped. (optional)