Salta ai contenuti
ricarica intelligente

LG Heat pump water heater (ThinQ)

Controls LG heat pump water heaters (e.g. WH27S) via the LG ThinQ Connect cloud API. A personal access token (PAT) must be created at https://connect-pat.lgthinq.com with the permissions "view devices", "view device status" and "control devices". evcc sets the water heater target temperature: the normal temperature outside of boost, the boost temperature during boost.

Parametri

NomeDescrizioneValoreLivello
tokenPersonal access token (PAT)facoltativo
countryCountry code

Country code of the LG account (ISO 3166-1 alpha-2)

Predefinito: DE
facoltativo
deviceDevice ID

Required if multiple water heaters are present in the account

facoltativo
normal [°C]Normal temperature

Target temperature outside of boost

Predefinito: 50
facoltativo
setpoint [°C]Boost temperature

Target temperature during boost, must exceed the normal temperature

Predefinito: 60
facoltativo
cacheCache

Time interval for data refresh

Predefinito: 1m
Esempio: 5m
avanzato
Esempio di configurazione per evcc.yaml

Se preferisci non configurare il dispositivo dall’interfaccia, puoi usare questo blocco YAML.

chargers:
- name: my_heating
type: template
template: lg-thinq
token: # Personal access token (PAT)
country: DE # Country code, Country code of the LG account (ISO 3166-1 alpha-2) (optional)
device: # Device ID, Required if multiple water heaters are present in the account (optional)
normal: 50 # Normal temperature (°C), Target temperature outside of boost (optional)
setpoint: 60 # Boost temperature (°C), Target temperature during boost, must exceed the normal temperature (optional)
cache: 1m # Cache, Time interval for data refresh (optional)