Use the local web interface of AC•THOR to set the value "Power timeout" to a value slightly higher (e.g. + 5s) than the interval time of evcc. Use control type "Modbus TCP" and set loadpoint minimal current to 0.125A. If the heating element at the controlled output has < 9 kW, the scaling factor has to be calculated as follows: scale = 9000 / nominal power of the connected heater.

Operation mode M3: 9 + 9 kW with an additional heater connected to the relay output is supported. Without load measurement using my-PV meter, the "Load at relay" setting in the local web interface of the AC•THOR must be set to match the nominal power of the heating element at the relay. If the heater at the controlled output has < 9 kW, AC•THOR firmware a0022401 or higher is required and the value for "Load at relay" must be converted using the scaling factor as follows: Load at relay = nominal power of the heater at the relay * scale factor

Funzionalità supportate

  • Contatore integrato: Supporto per un contatore integrato.

Parametri

NomeDescrizioneValoreLivello
idID Modbus
Predefinito: 1
intobbligatorio
hostIndirizzo IP o hostname
Esempio: 192.0.2.2
obbligatorio
portPorta
Predefinito: 502
intobbligatorio
tempsourceTemperature source
Predefinito: 1
facoltativo
scaleScale factor for power target value
Predefinito: 1
facoltativo
Esempio di configurazione per evcc.yaml

Se preferisci non configurare il dispositivo dall’interfaccia, puoi usare questo blocco YAML.

chargers:
- name: my_heating
type: template
template: ac-thor
# Modbus TCP
modbus: tcpip
id: 1
host: # Hostname
port: 502 # Port
tempsource: 1 # Temperature source, [1, 2, 3] (optional)
scale: 1 # Scale factor for power target value, optional