batterX Home

Funzionalità supportate

  • Controllo batteria: Controllo esterno della carica e della scarica della batteria domestica tramite evcc.

Ambiti di utilizzo

  • Contatore di rete
  • Produzione solare
  • Batteria

Parametri

NomeDescrizioneValoreLivello
hostIP address or hostname
Esempio: 192.0.2.2
facoltativo
portPort
Predefinito: 80
facoltativo
externalpvNeeded when a second solar inverter is connected.

This parameter is needed when the BatterX station is connected to another solar inverter. The total produced solar power can so be reported through one system. Further auxilary solar inverters do not need to be connected to evcc.

Predefinito: true
facoltativo
capacity [kWh]Battery capacity
Esempio: 50
facoltativo
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Predefinito: 0
Esempio: 25
facoltativo
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and for grid charging.

Predefinito: 100
Esempio: 95
facoltativo
maxchargepower [W]Maximum charge power

For forced charging of the battery.

avanzato
maxdischargepower [W]Maximum discharge power

Maximum discharge power of the storage.

avanzato
Esempio di configurazione per evcc.yaml

Se preferisci non configurare il dispositivo dall’interfaccia, puoi usare questo blocco YAML.

meters:
- name: my_grid
type: template
template: batterX
usage: grid
host: 192.0.2.2 # IP address or hostname
port: 80 # Port, optional
externalpv: true # Needed when a second solar inverter is connected., This parameter is needed when the BatterX station is connected to another solar inverter. The total produced solar power can so be reported through one system. Further auxilary solar inverters do not need to be connected to evcc. (optional)
meters:
- name: my_pv
type: template
template: batterX
usage: pv
host: 192.0.2.2 # IP address or hostname
port: 80 # Port, optional
externalpv: true # Needed when a second solar inverter is connected., This parameter is needed when the BatterX station is connected to another solar inverter. The total produced solar power can so be reported through one system. Further auxilary solar inverters do not need to be connected to evcc. (optional)
meters:
- name: my_battery
type: template
template: batterX
usage: battery
host: 192.0.2.2 # IP address or hostname
port: 80 # Port, optional
externalpv: true # Needed when a second solar inverter is connected., This parameter is needed when the BatterX station is connected to another solar inverter. The total produced solar power can so be reported through one system. Further auxilary solar inverters do not need to be connected to evcc. (optional)
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional)
maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional)
maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)