To use the EcoFlow Stream meter you need:

  • A valid Access Key from the EcoFlow Developer Console
  • The corresponding Secret Key
  • The main device serial number of your Stream system

These credentials can be obtained through the EcoFlow Developer Console after registering your application.

In normal operation the Backup Reserve is set to minsoc, for grid charging to maxsoc.

Note: Active battery control overwrites the Backup Reserve configured in the EcoFlow app. The device requires the Backup Reserve to exceed the discharge limit by 3, lower minsoc values are raised accordingly. Without minsoc the battery discharges down to the device's own discharge limit.

Funzionalità supportate

  • Controllo batteria: Controllo esterno della carica e della scarica della batteria domestica tramite evcc.

Ambiti di utilizzo

  • Contatore di rete
  • Produzione solare
  • Batteria

Parametri

NomeDescrizioneValoreLivello
accesskeyAccess Key

Access Key from EcoFlow Developer Console

facoltativo
secretkeySecret Key

Secret Key from EcoFlow Developer Console

facoltativo
serialSerial

Serial number of the main device in your Stream system, normally the first device of your system

facoltativo
capacity [kWh]Battery capacity
Esempio: 50
facoltativo
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Predefinito: 0
Esempio: 25
facoltativo
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and for grid charging.

Predefinito: 100
Esempio: 95
facoltativo
regionAPI Region

If you sometimes see error code 8513, like for example Starlink users do, automatic region detection fails. Here, you can set the API region manually. Possible values: auto (default), europe, or america.

Predefinito: auto
avanzato
cacheCache

Time interval for data refresh

Predefinito: 30s
Esempio: 5m
avanzato
maxchargepower [W]Maximum charge power

For forced charging of the battery.

avanzato
maxdischargepower [W]Maximum discharge power

Maximum discharge power of the storage.

avanzato
Esempio di configurazione per evcc.yaml

Se preferisci non configurare il dispositivo dall’interfaccia, puoi usare questo blocco YAML.

meters:
- name: my_grid
type: template
template: ecoflow-stream
usage: grid
accesskey: # Access Key, Access Key from EcoFlow Developer Console
secretkey: # Secret Key, Secret Key from EcoFlow Developer Console
serial: # Serial, Serial number of the main device in your Stream system, normally the first device of your system
region: auto # API Region, If you sometimes see error code 8513, like for example Starlink users do, automatic region detection fails. Here, you can set the API region manually. Possible values: auto (default), europe, or america. [auto, europe, america] (optional)
cache: 30s # Cache, Time interval for data refresh (optional)
meters:
- name: my_pv
type: template
template: ecoflow-stream
usage: pv
accesskey: # Access Key, Access Key from EcoFlow Developer Console
secretkey: # Secret Key, Secret Key from EcoFlow Developer Console
serial: # Serial, Serial number of the main device in your Stream system, normally the first device of your system
region: auto # API Region, If you sometimes see error code 8513, like for example Starlink users do, automatic region detection fails. Here, you can set the API region manually. Possible values: auto (default), europe, or america. [auto, europe, america] (optional)
cache: 30s # Cache, Time interval for data refresh (optional)
meters:
- name: my_battery
type: template
template: ecoflow-stream
usage: battery
accesskey: # Access Key, Access Key from EcoFlow Developer Console
secretkey: # Secret Key, Secret Key from EcoFlow Developer Console
serial: # Serial, Serial number of the main device in your Stream system, normally the first device of your system
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional)
region: auto # API Region, If you sometimes see error code 8513, like for example Starlink users do, automatic region detection fails. Here, you can set the API region manually. Possible values: auto (default), europe, or america. [auto, europe, america] (optional)
cache: 30s # Cache, Time interval for data refresh (optional)
maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional)