Salta ai contenuti
ricarica intelligente

Fronius Solar API V1

Solar API should only be used as fallback. Integration via Modbus is preferred.

Username and password are only required for active battery control.

Attention: Active battery control should only be used if no other settings for time-dependent battery control were made in the inverter configuration under "Energy Management" - "Battery Management", as existing settings will be overwritten. Choose corresponding configuration URI!

Funzionalità supportate

  • Controllo batteria: Controllo esterno della carica e della scarica della batteria domestica tramite evcc.

Ambiti di utilizzo

  • Contatore di rete
  • Produzione solare
  • Batteria

Parametri

NomeDescrizioneValoreLivello
hostIP address or hostname
Esempio: 192.0.2.2
facoltativo
userUsername (for active battery control)

e.g. email address, user id, etc.

Predefinito: customer
facoltativo
passwordPassword (for active battery control)

Service account password

facoltativo
capacity [kWh]Battery capacity
Esempio: 50
facoltativo
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Predefinito: 0
Esempio: 25
facoltativo
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and for grid charging.

Predefinito: 100
Esempio: 95
facoltativo
batteryconfiguriBattery configuration URI

Firmware starting with 1.36.5-1 requires /api/config.

Predefinito: /config
avanzato
maxchargepower [W]Maximum charge power

For forced charging of the battery.

avanzato
maxdischargepower [W]Maximum discharge power

Maximum discharge power of the storage.

avanzato
cacheCache

Time interval for data refresh

Predefinito: 1s
Esempio: 5m
avanzato
Esempio di configurazione per evcc.yaml

Se preferisci non configurare il dispositivo dall’interfaccia, puoi usare questo blocco YAML.

meters:
- name: my_grid
type: template
template: fronius-solarapi-v1
usage: grid
host: 192.0.2.2 # IP address or hostname
user: customer # Username (for active battery control), e.g. email address, user id, etc. (optional)
password: # Password (for active battery control), Service account password (optional)
batteryconfiguri: /config # Battery configuration URI, Firmware starting with 1.36.5-1 requires /api/config. [/config, /api/config] (optional)
cache: 1s # Cache, Time interval for data refresh (optional)
meters:
- name: my_pv
type: template
template: fronius-solarapi-v1
usage: pv
host: 192.0.2.2 # IP address or hostname
user: customer # Username (for active battery control), e.g. email address, user id, etc. (optional)
password: # Password (for active battery control), Service account password (optional)
batteryconfiguri: /config # Battery configuration URI, Firmware starting with 1.36.5-1 requires /api/config. [/config, /api/config] (optional)
cache: 1s # Cache, Time interval for data refresh (optional)
meters:
- name: my_battery
type: template
template: fronius-solarapi-v1
usage: battery
host: 192.0.2.2 # IP address or hostname
user: customer # Username (for active battery control), e.g. email address, user id, etc. (optional)
password: # Password (for active battery control), Service account password (optional)
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional)
batteryconfiguri: /config # Battery configuration URI, Firmware starting with 1.36.5-1 requires /api/config. [/config, /api/config] (optional)
maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional)
maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)
cache: 1s # Cache, Time interval for data refresh (optional)