Modbus TCP requires activation within the communication settings of the inverter using an "installer account", see Modbus TCP Activation Guide.

Grid and Battery require the Huawei Smart Power Sensor (DDSU/DTSU666 or SmartPS).

Multiple LUNA2000 towers connected to the same SUN2000 inverter are configured as a single logical battery.

Curtailment will limit the export power to the desired percentage of the maximum AC power. The inverter will automatically limit the PV power to achieve this.

Funzionalità supportate

  • Controllo batteria: Controllo esterno della carica e della scarica della batteria domestica tramite evcc.
  • Limitabile: La produzione dell’inverter può essere limitata (ad es. § 9 EEG). Vedi Limite esterno.
  • Riducibile: La potenza assorbita può essere ridotta (ad es. § 14a EnWG). Vedi Limite esterno.

Ambiti di utilizzo

  • Contatore di rete
  • Produzione solare
  • Batteria

Parametri

Modbus
NomeDescrizioneValoreLivello
idID Modbus
Predefinito: 1
intobbligatorio
deviceNome dispositivo

Adattatore USB-RS485

Esempio: /dev/ttyUSB0
obbligatorio
baudrateBaudrate
Predefinito: 9600
obbligatorio
comsetComSet

Parametro di comunicazione dell’adattatore

Predefinito: 8N1
obbligatorio
hostIndirizzo IP o hostname
Esempio: 192.0.2.2
obbligatorio
portPorta
Predefinito: 502
intobbligatorio
maxchargepower [W]Maximum charge power

For forced charging of the battery.

facoltativo
maxdischargepower [W]Maximum discharge power

Maximum discharge power of the storage.

facoltativo
capacity [kWh]Battery capacity
Esempio: 50
facoltativo
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Predefinito: 0
Esempio: 25
facoltativo
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and for grid charging.

Predefinito: 100
Esempio: 95
facoltativo
maxacpower [W]Maximum AC power of the hybrid inverter
Predefinito: 0
Esempio: 5000
avanzato
forceacchargingInverter cascade

Keep AC charging active (except for when being dimmed) to charge the storage from other inverters via AC. May prevent standby with older firmware versions.

Predefinito: false
avanzato
Esempio di configurazione per evcc.yaml

Se preferisci non configurare il dispositivo dall’interfaccia, puoi usare questo blocco YAML.

meters:
- name: my_grid
type: template
template: huawei-sun2000-hybrid
usage: grid
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
timeout: 5s # optional
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: # Hostname
port: 502 # Port
timeout: 5s # optional
# Modbus TCP
modbus: tcpip
id: 1
host: # Hostname
port: 502 # Port
timeout: 5s # optional
meters:
- name: my_pv
type: template
template: huawei-sun2000-hybrid
usage: pv
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
timeout: 5s # optional
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: # Hostname
port: 502 # Port
timeout: 5s # optional
# Modbus TCP
modbus: tcpip
id: 1
host: # Hostname
port: 502 # Port
timeout: 5s # optional
maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optional
meters:
- name: my_battery
type: template
template: huawei-sun2000-hybrid
usage: battery
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
timeout: 5s # optional
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: # Hostname
port: 502 # Port
timeout: 5s # optional
# Modbus TCP
modbus: tcpip
id: 1
host: # Hostname
port: 502 # Port
timeout: 5s # optional
maxchargepower: # Maximum charge power (W), For forced charging of the battery.
maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage.
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional)
forceaccharging: false # Inverter cascade, Keep AC charging active (except for when being dimmed) to charge the storage from other inverters via AC. May prevent standby with older firmware versions. (optional)