Salta ai contenuti
ricarica intelligente

Qcells Hybrid-Inverter (Cloud)

The Qcells hybrid inverter has to be registered in the QcellsCloud.

Attention: Values can only be fetched every 150s and then also can be 5 minutes old. Charging by PV will not be optimal because of this! Only use as fallback if no local access is available.

Ambiti di utilizzo

  • Contatore di rete
  • Produzione solare
  • Batteria

Parametri

NomeDescrizioneValoreLivello
tokenidQcellsCloud TokenID

Go to qhome-ess-g3.q-cells.eu or qhome-ess-g3.q-cells.us and take the value of "ObtaintokenID".

facoltativo
serialSerial number

Go to qhome-ess-g3.q-cells.eu or qhome-ess-g3.q-cells.us and take the value of registration number.

facoltativo
regionRegion
Predefinito: EU
facoltativo
capacity [kWh]Battery capacity
Esempio: 50
facoltativo
minsoc [%]Minimum charge

Lower limit as configured on the battery system. Used by optimizer.

Predefinito: 0
Esempio: 25
facoltativo
maxsoc [%]Maximum charge

Upper limit as configured on the battery system. Used by optimizer and for grid charging.

Predefinito: 100
Esempio: 95
facoltativo
maxchargepower [W]Maximum charge power

For forced charging of the battery.

avanzato
maxdischargepower [W]Maximum discharge power

Maximum discharge power of the storage.

avanzato
Esempio di configurazione per evcc.yaml

Se preferisci non configurare il dispositivo dall’interfaccia, puoi usare questo blocco YAML.

meters:
- name: my_grid
type: template
template: qcells-hybrid-cloud
usage: grid
tokenid: # QcellsCloud TokenID, Go to [qhome-ess-g3.q-cells.eu](https://qhome-ess-g3.q-cells.eu/#/api/) or [qhome-ess-g3.q-cells.us](https://qhome-ess-g3.q-cells.us/#/api/) and take the value of "ObtaintokenID".
serial: # Serial number, Go to [qhome-ess-g3.q-cells.eu](https://qhome-ess-g3.q-cells.eu/blue/#/inverter) or [qhome-ess-g3.q-cells.us](https://qhome-ess-g3.q-cells.us/blue/#/inverter) and take the value of registration number.
region: EU # Region, [EU, US] (optional)
meters:
- name: my_pv
type: template
template: qcells-hybrid-cloud
usage: pv
tokenid: # QcellsCloud TokenID, Go to [qhome-ess-g3.q-cells.eu](https://qhome-ess-g3.q-cells.eu/#/api/) or [qhome-ess-g3.q-cells.us](https://qhome-ess-g3.q-cells.us/#/api/) and take the value of "ObtaintokenID".
serial: # Serial number, Go to [qhome-ess-g3.q-cells.eu](https://qhome-ess-g3.q-cells.eu/blue/#/inverter) or [qhome-ess-g3.q-cells.us](https://qhome-ess-g3.q-cells.us/blue/#/inverter) and take the value of registration number.
region: EU # Region, [EU, US] (optional)
meters:
- name: my_battery
type: template
template: qcells-hybrid-cloud
usage: battery
tokenid: # QcellsCloud TokenID, Go to [qhome-ess-g3.q-cells.eu](https://qhome-ess-g3.q-cells.eu/#/api/) or [qhome-ess-g3.q-cells.us](https://qhome-ess-g3.q-cells.us/#/api/) and take the value of "ObtaintokenID".
serial: # Serial number, Go to [qhome-ess-g3.q-cells.eu](https://qhome-ess-g3.q-cells.eu/blue/#/inverter) or [qhome-ess-g3.q-cells.us](https://qhome-ess-g3.q-cells.us/blue/#/inverter) and take the value of registration number.
region: EU # Region, [EU, US] (optional)
capacity: 50 # Battery capacity (kWh), optional
minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional)
maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional)
maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional)
maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)