Sigenergy Sigen Hybrid
Modbus TCP must be enabled in the configuration app with installer rights. This option is not available in the mySigen app for customers.
Funzionalità supportate
- Controllo batteria: Controllo esterno della carica e della scarica della batteria domestica tramite evcc.
Ambiti di utilizzo
- Contatore di rete
- Produzione solare
- Batteria
Parametri
| Nome | Descrizione | Valore | Livello |
|---|---|---|---|
id | ID Modbus | int | obbligatorio |
host | Indirizzo IP o hostname | obbligatorio | |
port | Porta | int | obbligatorio |
capacity [kWh] | Battery capacity | facoltativo | |
minsoc [%] | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | facoltativo | |
maxsoc [%] | Maximum charge Upper limit as configured on the battery system. Used by optimizer and for grid charging. | facoltativo | |
maxacpower [W] | Maximum AC power of the hybrid inverter | avanzato | |
gateway | Sigen Energy Gateway installed Uses the "Backup SoC" register (40046) instead of "Discharge Cut-Off SoC" (40048) to block discharge. This keeps the house powered during a grid outage. | avanzato | |
maxchargepower [W] | Maximum charge power For forced charging of the battery. | avanzato | |
maxdischargepower [W] | Maximum discharge power Maximum discharge power of the storage. | avanzato |
Esempio di configurazione per evcc.yaml
Se preferisci non configurare il dispositivo dall’interfaccia, puoi usare questo blocco YAML.
meters: - name: my_grid type: template template: sigenergy usage: grid
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 502 # Portmeters: - name: my_pv type: template template: sigenergy usage: pv
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 502 # Port maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optionalmeters: - name: my_battery type: template template: sigenergy usage: battery
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 502 # Port capacity: 50 # Battery capacity (kWh), optional minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional) maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional) gateway: false # Sigen Energy Gateway installed, Uses the "Backup SoC" register (40046) instead of "Discharge Cut-Off SoC" (40048) to block discharge. This keeps the house powered during a grid outage. (optional) maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional) maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)