SofarSolar HYD 5…20K-3PH
For more details on how to establish a connection to the inverter see the Sofar Solar installation doc at homeassistant-solax-modbus.readthedocs.io.
Funzionalità supportate
- Controllo batteria: Controllo esterno della carica e della scarica della batteria domestica tramite evcc.
Ambiti di utilizzo
- Contatore di rete
- Produzione solare
- Batteria
Parametri
| Nome | Descrizione | Valore | Livello |
|---|---|---|---|
id | ID Modbus | int | obbligatorio |
device | Nome dispositivo Adattatore USB-RS485 | obbligatorio | |
baudrate | Baudrate | obbligatorio | |
comset | ComSet Parametro di comunicazione dell’adattatore | obbligatorio | |
host | Indirizzo IP o hostname | obbligatorio | |
port | Porta | int | obbligatorio |
capacity [kWh] | Battery capacity | facoltativo | |
minsoc [%] | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | facoltativo | |
maxsoc [%] | Maximum charge Upper limit as configured on the battery system. Used by optimizer and for grid charging. | facoltativo | |
maxacpower [W] | Maximum AC power of the hybrid inverter | avanzato | |
storageunit | Battery storage unit index In case of a BTS storage not the address of a BTS 5K battery module, but the storage tower (BTS 5K-BDU control unit with 1-4 BTS 5K modules). | avanzato | |
defaultmode | Default mode for battery control Valid values are 0 (self use), 1 (time of use), 2 (timing mode), 4 (peak-shaving mode) | avanzato | |
externalpower | Include external power Includes all connected external sources, like the power generation of cascaded inverters, into the PV power calculation. | avanzato | |
maxchargepower [W] | Maximum charge power For forced charging of the battery. | avanzato | |
maxdischargepower [W] | Maximum discharge power Maximum discharge power of the storage. | avanzato |
Esempio di configurazione per evcc.yaml
Se preferisci non configurare il dispositivo dall’interfaccia, puoi usare questo blocco YAML.
meters: - name: my_grid type: template template: sofarsolar-g3 usage: grid
# RS485 via adapter (Modbus RTU) modbus: rs485serial id: 1 device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200 comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU) modbus: rs485tcpip id: 1 host: # Hostname port: 8899 # Port
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 8899 # Portmeters: - name: my_pv type: template template: sofarsolar-g3 usage: pv
# RS485 via adapter (Modbus RTU) modbus: rs485serial id: 1 device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200 comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU) modbus: rs485tcpip id: 1 host: # Hostname port: 8899 # Port
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 8899 # Port maxacpower: 0 # Maximum AC power of the hybrid inverter (W), optional externalpower: # Include external power, Includes all connected external sources, like the power generation of cascaded inverters, into the PV power calculation. (optional)meters: - name: my_battery type: template template: sofarsolar-g3 usage: battery
# RS485 via adapter (Modbus RTU) modbus: rs485serial id: 1 device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200 comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU) modbus: rs485tcpip id: 1 host: # Hostname port: 8899 # Port
# Modbus TCP modbus: tcpip id: 1 host: # Hostname port: 8899 # Port capacity: 50 # Battery capacity (kWh), optional minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional) maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional) storageunit: 1 # Battery storage unit index, In case of a BTS storage not the address of a BTS 5K battery module, but the storage tower (BTS 5K-BDU control unit with 1-4 BTS 5K modules). (optional) defaultmode: 0 # Default mode for battery control, Valid values are 0 (self use), 1 (time of use), 2 (timing mode), 4 (peak-shaving mode) (optional) maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional) maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)