Solplanet AI-Dongle LAN (local HTTP API)
Uses the AI-Dongle local HTTP API (e.g. BA121T-30) instead of Modbus TCP.
The inverter serial number (isn) can be read via http://<host>:8484/getdev.cgi?device=2.
Battery control charge power is fixed at 5000 W.
Funzionalità supportate
- Controllo batteria: Controllo esterno della carica e della scarica della batteria domestica tramite evcc.
Ambiti di utilizzo
- Contatore di rete
- Produzione solare
- Batteria
Parametri
| Nome | Descrizione | Valore | Livello |
|---|---|---|---|
host | IP address or hostname | facoltativo | |
serial | Inverter serial number (isn) | facoltativo | |
capacity [kWh] | Battery capacity | facoltativo | |
minsoc [%] | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | facoltativo | |
maxsoc [%] | Maximum charge Upper limit as configured on the battery system. Used by optimizer and for grid charging. | facoltativo | |
maxchargepower [W] | Maximum charge power For forced charging of the battery. | avanzato | |
maxdischargepower [W] | Maximum discharge power Maximum discharge power of the storage. | avanzato |
Esempio di configurazione per evcc.yaml
Se preferisci non configurare il dispositivo dall’interfaccia, puoi usare questo blocco YAML.
meters: - name: my_grid type: template template: solplanet-ai-dongle usage: grid host: 192.0.2.2 # IP address or hostname serial: # Inverter serial number (isn)meters: - name: my_pv type: template template: solplanet-ai-dongle usage: pv host: 192.0.2.2 # IP address or hostname serial: # Inverter serial number (isn)meters: - name: my_battery type: template template: solplanet-ai-dongle usage: battery host: 192.0.2.2 # IP address or hostname serial: # Inverter serial number (isn) capacity: 50 # Battery capacity (kWh), optional minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional) maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional) maxchargepower: # Maximum charge power (W), For forced charging of the battery. (optional) maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional)