Sonnen sonnenBatterie
For active battery control, the "JSON Write API" must be activated via the sonnenBatterie web interface (under Software-Integration) and the API token generated there must be entered in the battery configuration under token.
The two operating modes supported for the sonnenBatterie are "self-consumption" (default) and "time-of-use". The mode can be adapted to the configuration of the sonnenBatterie via the 'defaultmode' parameter.
The power for grid charging can be adapted to the inverter power of the sonnenBatterie via the maxchargepower parameter.
Funzionalità supportate
- Controllo batteria: Controllo esterno della carica e della scarica della batteria domestica tramite evcc.
Ambiti di utilizzo
- Contatore di rete
- Produzione solare
- Batteria
Parametri
| Nome | Descrizione | Valore | Livello |
|---|---|---|---|
host | IP address or hostname | facoltativo | |
defaultmode | Default mode for battery control Inverter falls back to this mode after charging the battery or after stopping discharge. | facoltativo | |
port | Port | facoltativo | |
capacity [kWh] | Battery capacity | facoltativo | |
minsoc [%] | Minimum charge Lower limit as configured on the battery system. Used by optimizer. | facoltativo | |
maxsoc [%] | Maximum charge Upper limit as configured on the battery system. Used by optimizer and for grid charging. | facoltativo | |
token | Token API Token (required for active battery control) | facoltativo | |
maxchargepower [W] | Maximum charge power For forced charging of the battery. | avanzato | |
maxdischargepower [W] | Maximum discharge power Maximum discharge power of the storage. | avanzato | |
cache | Cache Time interval for data refresh | avanzato |
Esempio di configurazione per evcc.yaml
Se preferisci non configurare il dispositivo dall’interfaccia, puoi usare questo blocco YAML.
meters: - name: my_grid type: template template: sonnenbatterie usage: grid host: 192.0.2.2 # IP address or hostname port: 8080 # Port, optional cache: 1s # Cache, Time interval for data refresh (optional)meters: - name: my_pv type: template template: sonnenbatterie usage: pv host: 192.0.2.2 # IP address or hostname port: 8080 # Port, optional cache: 1s # Cache, Time interval for data refresh (optional)meters: - name: my_battery type: template template: sonnenbatterie usage: battery host: 192.0.2.2 # IP address or hostname defaultmode: self-consumption # Default mode for battery control, Inverter falls back to this mode after charging the battery or after stopping discharge. [self-consumption, time-of-use] port: 8080 # Port, optional capacity: 50 # Battery capacity (kWh), optional minsoc: 0 # Minimum charge (%), Lower limit as configured on the battery system. Used by optimizer. (optional) maxsoc: 100 # Maximum charge (%), Upper limit as configured on the battery system. Used by optimizer and for grid charging. (optional) token: # Token, API Token (required for active battery control) (optional) maxchargepower: 3300 # Maximum charge power (W), For forced charging of the battery. (optional) maxdischargepower: # Maximum discharge power (W), Maximum discharge power of the storage. (optional) cache: 1s # Cache, Time interval for data refresh (optional)